SAIPAN, MP —
OSHA Inspection: HBR INTERNATIONAL INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HBR INTERNATIONAL INC. in GARAPAN, SAIPAN, MP 96950 (NAICS 236220). OSHA activity number 343767133.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HBR INTERNATIONAL INC.
- Site address
- GARAPAN
- City
- SAIPAN
- State
- MP
- ZIP
- 96950
- Mailing
- P.O. BOX 5756 CHRB, SAIPAN, MP 96950
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 40
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.303 B01
- Issued
- Apr 12, 2019
- Penalty
- Initial $5,304 · Current $3,713 Reduced
General-duty citation text
29 CFR 1926.303(b)(1): Grinding machines were not equipped with safety guards in conformance with the requirements of ANSI B7.1-1970, Safety Code for the Use, Care, and Protection of abrasive wheels, and paragraph (d) of this section. In the middle of the perimeter fence area: A grinder without a safety guard was used to cut rebar. Employees were exposed to cut, and laceration hazards
Recent events (2)
- — I (S) $3712.8
- — Z (S) $5304
1926.403 B02
- Issued
- Apr 12, 2019
- Abate by
- Apr 19, 2019
- Penalty
- Initial $3,978 · Current $2,785 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: In the middle of the perimeter fence: An extension cord with a receptacle box designed to be installed inside of walls was used to provide power to a circular saw. Employees were exposed to electrical hazards.
Recent events (2)
- — I (S) $2784.6
- — Z (S) $3978
1926.405 B01
- Issued
- Apr 12, 2019
- Abate by
- Apr 19, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(b)(1): Openings in boxes, cabinets, and fittings through which conductors entered were not effectively closed In the middle of the perimeter fence: The opening where the conductors entered the receptacle box on the end of the extension cord used to provide power to a circular saw was not closed. Employees were exposed to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 B02
- Issued
- Apr 12, 2019
- Abate by
- Apr 19, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: In the middle of the perimeter fence: A receptacle box used to power the grinder was missing the cover plate. Employees were exposed to electrical hazards
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at HBR International INC.
View HBR International INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in MP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343767133.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.