Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HBR INTERNATIONAL INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HBR INTERNATIONAL INC. in GARAPAN, SAIPAN, MP 96950 (NAICS 236220). OSHA activity number 343767133.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HBR International INC. — free Get an email when a new federal OSHA severe-injury report for HBR International INC. is published. One employer, no account, unsubscribe in one click.
Site address
GARAPAN
City
SAIPAN
State
MP
ZIP
96950
Mailing
P.O. BOX 5756 CHRB, SAIPAN, MP 96950
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
40
Ownership type
A

4 citations on file for this inspection.

1926.303 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 12, 2019
Penalty
Initial $5,304 · Current $3,713 Reduced
29 CFR 1926.303(b)(1): Grinding machines were not equipped with safety guards in conformance with the requirements of ANSI B7.1-1970, Safety Code for the Use, Care, and Protection of abrasive wheels, and paragraph (d) of this section.  In the middle of the perimeter fence area: A grinder without a safety guard was used to cut rebar. Employees were exposed to cut, and laceration hazards
Recent events (2)
  • — I (S) $3712.8
  • — Z (S) $5304

1926.403 B02

Serious Gravity 1 2 instances 2 exposed
Issued
Apr 12, 2019
Abate by
Apr 19, 2019
Penalty
Initial $3,978 · Current $2,785 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  In the middle of the perimeter fence: An extension cord with a receptacle box designed to be installed inside of walls was used to provide power to a circular saw. Employees were exposed to electrical hazards.
Recent events (2)
  • — I (S) $2784.6
  • — Z (S) $3978

1926.405 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 12, 2019
Abate by
Apr 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(1): Openings in boxes, cabinets, and fittings through which conductors entered were not effectively closed  In the middle of the perimeter fence: The opening where the conductors entered the receptacle box on the end of the extension cord used to provide power to a circular saw was not closed. Employees were exposed to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 12, 2019
Abate by
Apr 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:  In the middle of the perimeter fence: A receptacle box used to power the grinder was missing the cover plate. Employees were exposed to electrical hazards
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View HBR International INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343767133.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.