Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CLIMCO COILS COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CLIMCO COILS COMPANY in 701 KLIMSTRA COURT, MORRISON, IL 61270 (NAICS 332710). OSHA activity number 343767745.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Climco Coils Company — free Get an email when a new federal OSHA severe-injury report for Climco Coils Company is published. One employer, no account, unsubscribe in one click.
Site address
701 KLIMSTRA COURT
City
MORRISON
State
IL
ZIP
61270
Mailing
701 KLIMSTRA COURT, MORRISON, IL 61270
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
175
Ownership type
A

1 citation on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 25 exposed
Issued
Feb 22, 2019
Abate by
May 1, 2019
Penalty
Initial $8,525 · Current $5,100 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc:    Machining area, HAAS CNC mills #1 - #9: on or about February 7, 2019, mill operators were exposed to moving parts in danger zones.  Safety devices (door interlock switches) for detecting opening of the sliding access doors were bypassed and inoperative. The interlocks were not used to ensure that the operating cycle stopped when the doors were opened, as they were mounted on top of the immovable enclosure with their keys permanently inserted into receivers.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $5100
  • — Z (S) $8525

View Climco Coils Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343767745.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.