OSHA Inspection: DECOR CABINETS SOUTHEAST, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DECOR CABINETS SOUTHEAST, LLC in 1975 DELTA DRIVE, GAINESVILLE, GA 30501 (NAICS 337110). OSHA activity number 343769659.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Decor Cabinets Southeast, LLC for free Get an email when a new federal OSHA severe-injury report for Decor Cabinets Southeast, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1975 DELTA DRIVE
City
GAINESVILLE
State
GA
ZIP
30501
Mailing
6965 HUNTERS BRANCH DRIVE, ATLANTA, GA 30328
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
10
Ownership type
Private (A)

8 citations on file for this inspection.

1910.157 C01

Serious Gravity 5 3 instances 4 exposed
Issued
Aug 7, 2019
Abate by
Aug 26, 2019
Penalty
Initial $3,410 · Current $3,410
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  On or about 2/8/2019 throughout the shop, workers expected to perform extinguishing of incipient level fires, were exposed to inhalation and burn hazards where the portable fire extinguishers were not properly mounted at locations including but not limited to:  a. Production floor - resting on workbench b. Loft - resting on floor c. Production floor - blocked by flammable chemical storage cabinet
Recent events (1)
  • · Z (S) $3410

1910.157 E02

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 7, 2019
Abate by
Aug 26, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  On or about 2/8/2019 throughout the shop, workers expected to perform extinguishing of incipient level fires were exposed to inhalation and burn hazards where the portable fire extinguishers had not been inspected since December 2016.
Recent events (1)
  • · Z (S) $0

1910.157 E03

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 7, 2019
Abate by
Aug 26, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  On or about 2/8/2019 throughout the shop, workers expected to perform extinguishing of incipient level fires, were exposed to inhalation and burn hazards where the portable fire extinguishers were not inspected since December 2016.
Recent events (1)
  • · Z (S) $0

1910.157 G01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 7, 2019
Abate by
Aug 26, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:  On or about 2/8/2019 throughout the shop, workers expected to perform extinguishing of incipient level fires were exposed to inhalation and burn hazards where they were not trained to do so.
Recent events (1)
  • · Z (S) $0

1910.212 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 7, 2019
Abate by
Aug 26, 2019
Penalty
Initial $3,978 · Current $3,978
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation and rotating parts:  On or about 2/8/2019 at the table saw, workers were exposed to amputation hazards while cutting laminate with the guard not installed.
Recent events (1)
  • · Z (S) $3978

1910.303 B02

Serious Gravity 5 3 instances 5 exposed
Issued
Aug 7, 2019
Abate by
Aug 26, 2019
Penalty
Initial $3,410 · Current $3,410
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a. On or about 2/8/2019, in the shop area, workers were exposed to electrical shock and burn hazards where the electrical 110V outlet was not hard mounted and was in use as a pendant attached to a flexible cord from the ceiling powering the Makita router S/N 6*7*445  b. On or about 2/8/2019, in the shop area, workers were exposed to electrical shock and burn hazards where the electrical 110V outlet was not hard mounted and was in use as a pendant attached to a flexible cord from the ceiling powering the DeWalt chop saw  c. On or about 2/8/2019, in the shop area, workers were exposed to electrical shock and burn hazards where the electrical 110 V outlet was not hard mounted and in use as a pendant attached to a flexible cord from the ceiling powering a pocket cutter and a yellow extension cord available for use.
Recent events (1)
  • · Z (S) $3410

1910.178 L01 I

Other-than-serious 1 instance 4 exposed
Issued
Aug 7, 2019
Abate by
Aug 26, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  On or about 2/8/2019, employees utilize a powered industrial truck to move product and materials throughout the facility.  Powered industrial truck operators were not trained or evaluated in accordance with the standard.
Recent events (1)
  • · Z (O) $0

1910.178 Q07

Other-than-serious 1 instance 4 exposed
Issued
Aug 7, 2019
Abate by
Aug 26, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:  On or about 2/8/2019, employees use a powered industrial truck to transport materials and product throughout the facility on a daily basis.  The powered industrial truck was not inspected before use.
Recent events (1)
  • · Z (O) $0