GAINESVILLE, GA ·
OSHA Inspection: DECOR CABINETS SOUTHEAST, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DECOR CABINETS SOUTHEAST, LLC in 1975 DELTA DRIVE, GAINESVILLE, GA 30501 (NAICS 337110). OSHA activity number 343769659.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DECOR CABINETS SOUTHEAST, LLC
- Site address
- 1975 DELTA DRIVE
- City
- GAINESVILLE
- State
- GA
- ZIP
- 30501
- Mailing
- 6965 HUNTERS BRANCH DRIVE, ATLANTA, GA 30328
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 10
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.157 C01
- Issued
- Aug 7, 2019
- Abate by
- Aug 26, 2019
- Penalty
- Initial $3,410 · Current $3,410
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On or about 2/8/2019 throughout the shop, workers expected to perform extinguishing of incipient level fires, were exposed to inhalation and burn hazards where the portable fire extinguishers were not properly mounted at locations including but not limited to: a. Production floor - resting on workbench b. Loft - resting on floor c. Production floor - blocked by flammable chemical storage cabinet
Recent events (1)
- · Z (S) $3410
1910.157 E02
- Issued
- Aug 7, 2019
- Abate by
- Aug 26, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: On or about 2/8/2019 throughout the shop, workers expected to perform extinguishing of incipient level fires were exposed to inhalation and burn hazards where the portable fire extinguishers had not been inspected since December 2016.
Recent events (1)
- · Z (S) $0
1910.157 E03
- Issued
- Aug 7, 2019
- Abate by
- Aug 26, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: On or about 2/8/2019 throughout the shop, workers expected to perform extinguishing of incipient level fires, were exposed to inhalation and burn hazards where the portable fire extinguishers were not inspected since December 2016.
Recent events (1)
- · Z (S) $0
1910.157 G01
- Issued
- Aug 7, 2019
- Abate by
- Aug 26, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: On or about 2/8/2019 throughout the shop, workers expected to perform extinguishing of incipient level fires were exposed to inhalation and burn hazards where they were not trained to do so.
Recent events (1)
- · Z (S) $0
1910.212 A01
- Issued
- Aug 7, 2019
- Abate by
- Aug 26, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation and rotating parts: On or about 2/8/2019 at the table saw, workers were exposed to amputation hazards while cutting laminate with the guard not installed.
Recent events (1)
- · Z (S) $3978
1910.303 B02
- Issued
- Aug 7, 2019
- Abate by
- Aug 26, 2019
- Penalty
- Initial $3,410 · Current $3,410
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. On or about 2/8/2019, in the shop area, workers were exposed to electrical shock and burn hazards where the electrical 110V outlet was not hard mounted and was in use as a pendant attached to a flexible cord from the ceiling powering the Makita router S/N 6*7*445 b. On or about 2/8/2019, in the shop area, workers were exposed to electrical shock and burn hazards where the electrical 110V outlet was not hard mounted and was in use as a pendant attached to a flexible cord from the ceiling powering the DeWalt chop saw c. On or about 2/8/2019, in the shop area, workers were exposed to electrical shock and burn hazards where the electrical 110 V outlet was not hard mounted and in use as a pendant attached to a flexible cord from the ceiling powering a pocket cutter and a yellow extension cord available for use.
Recent events (1)
- · Z (S) $3410
1910.178 L01 I
- Issued
- Aug 7, 2019
- Abate by
- Aug 26, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about 2/8/2019, employees utilize a powered industrial truck to move product and materials throughout the facility. Powered industrial truck operators were not trained or evaluated in accordance with the standard.
Recent events (1)
- · Z (O) $0
1910.178 Q07
- Issued
- Aug 7, 2019
- Abate by
- Aug 26, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: On or about 2/8/2019, employees use a powered industrial truck to transport materials and product throughout the facility on a daily basis. The powered industrial truck was not inspected before use.
Recent events (1)
- · Z (O) $0
More inspections at Decor Cabinets Southeast, LLC
View Decor Cabinets Southeast, LLC's full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343769659.