Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: FIVE STAR ARCHITECTURAL, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FIVE STAR ARCHITECTURAL, LLC in 68 GROGAN DRIVE, DAWSONVILLE, GA 30534 (NAICS 337212). OSHA activity number 343770608.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Five Star Architectural, LLC for free Get an email when a new federal OSHA severe-injury report for Five Star Architectural, LLC is published. One employer, no account, unsubscribe in one click.
Site address
68 GROGAN DRIVE
City
DAWSONVILLE
State
GA
ZIP
30534
Mailing
68 GROGAN DRIVE, DAWSONVILLE, GA 30534
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337212
Employees
37
Ownership type
A

14 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 5, 2019
Abate by
Aug 29, 2019
Penalty
Initial $6,630 · Current $4,641 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition:  Five Star Architectural, LLC, Dawsonville, GA - On or about 02/06/2019, the areas where the cutting was performed in the saw area had explosive dust on upper surfaces such as but not limited to, electrical outlets, cabinets and table surfaces, exposing employees to fire hazards.
Recent events (2)
  • · I (S) $4641
  • · Z (S) $6630

1910.107 B05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 5, 2019
Abate by
Sep 16, 2019
Penalty
Initial $6,630 · Current $4,641 Reduced
29 CFR 1910.107(b)(5)(i): The average air speed over the open face of the paint spray booth was less than 100 linear feet per minute. There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained.    Five Star Architectural, LLC, Dawsonville, GA - On or about 02/06/2019, employees were exposed to fire hazards while painting in a paint booth with flammable chemicals such as but not limited to Xpert Toner Base, Primer Sealer White, EZ Vinyl Sealer Gal, Duracoat Pre-Catalyzed Flat 10 Sheen Gal. The air velocity over the open face of the booth was on an average of 25-35 linear feet per minute. There were no visible gauges to ensure that the required air speed was maintained.
Recent events (2)
  • · I (S) $4641
  • · Z (S) $6630

1910.132 D01

Serious Gravity 5 2 instances 5 exposed
Issued
Aug 5, 2019
Abate by
Aug 29, 2019
Penalty
Initial $6,630 · Current $4,641 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  Five Star Architectural, LLC, Dawsonville, GA - On or about 02/06/2019, the employer did not assess the workplace to ensure that proper personal protective equipment was used where employees' eye and face were exposed to:  a. corrosive chemicals such as, but not limited to, Duracoat Pre-Catalyzed Flat 10 Sheen Gal, Klear Kote Clear Epoxy Hardener - employees only used gloves and safety glasses but not at all times.   b. staple guns with no proper personal protective equipment (eye protection) at all times - Employees with prescribed glasses did not wear safety glasses or prescribed safety glasses.
Recent events (2)
  • · I (S) $4641
  • · Z (S) $6630

1910.133 A01

Serious Gravity 5 2 instances 5 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:   Five Star Architectural, LLC, Dawsonville, GA - On or about 02/06/2019, the employer did not ensure that all employees used the appropriate eye and face protection while working with:  a. corrosive chemicals such as, but not limited to, Duracoat Pre-Catalyzed Flat 10 Sheen Gal, Klear Kote Clear Epoxy Hardener - employees only used safety glasses and not at all times.   b. staple guns with no proper personal protective equipment (eye protection) at all times - Employees with prescribed glasses did not wear safety glasses or prescribed safety glasses.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 C02 I

Serious Gravity 1 1 instance 12 exposed
Issued
Aug 5, 2019
Penalty
Initial $3,978 · Current $2,785 Reduced
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  Five Star Architectural, LLC, Dawsonville, GA - On or about 02/06/2019, employees working throughout the shop were provided with respirators (N95) for voluntary use. The employer did not provide the information contained in the Appendix D of the Respiratory Protection Standard.
Recent events (2)
  • · I (S) $2784.6
  • · Z (S) $3978

1910.134 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   Five Star Architectural, LLC, Dawsonville, GA - On or about 02/06/2019, employees were required to use of half face respirators while painting in the paint booth. The employer did not provide a medical evaluation to employees as required by the Respiratory Protection Standard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 F02

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  Five Star Architectural, LLC, Dawsonville, GA - On or about 02/06/2019, employees were required the use of half face respirators while painting in the paint booth. The employer did not provide the fit test to employees as required by the Respiratory Protection Standard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 G01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 5, 2019
Abate by
Aug 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i): The employer permitted respirators with tight-fitting facepieces to be worn by employees who have facial hair that came between the sealing surface of the facepiece and the face or interfered with valve function:  Five Star Architectural, LLC, Dawsonville, GA - On or about 02/06/2019, employees were required to use half face respirators while painting in the paint booth. The employer failed to enforce the proper use of the respirator as required by the Respiratory Protection Standard when allowing employees to use respirators with facial hair that came between the sealing surface of the facepiece and the face.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 K01

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 5, 2019
Abate by
Aug 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(1): The employer did not provide respirator training that ensured that each employee could demonstrate knowledge of at least the following elements: Why the respirator is necessary and how improper fit, usage, or maintenance can compromise the protective effect of the respirator; What the limitations and capabilities of the respirator are; How to use the respirator effectively in emergency situations, including situations in which the respirator malfunctions; How to inspect, put on and remove, use, and check the seals of the respirator; What the procedures are for maintenance and storage of the respirator, and How to recognize medical signs and symptoms that may limit or prevent the effective use of respirators:  Five Star Architectural, LLC, Dawsonville, GA - On or about 02/06/2019, employees were required to use half face respirators while painting in the paint booth. The employer did not provide all employees training on respirators to ensure the proper use of them, the procedures of maintenance, and the limitations of the respirators.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 5, 2019
Penalty
Initial $5,304 · Current $3,713 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   Five Star Architectural, LLC, Dawsonville, GA - On or about 02/06/2019, employees were exposed to corrosive chemicals such as but not limited to the Duracoat Pre-Catalyzed Flat 10 Sheen Gal, Klear Kote Clear Epoxy Hardener when the employer did not have a suitable facility for quick drenching or flushing eyes and body for immediate use in the paint area. The water in the eye wash station was not changed as per the manufacturer's recommendation. The water was not changed since the date of installation on 2016.
Recent events (2)
  • · I (S) $3712.8
  • · Z (S) $5304

1910.1200 E01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 5, 2019
Penalty
Initial $6,630 · Current $4,580 Reduced
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.    Five Star Architectural, LLC, Dawsonville, GA - On or about 02/06/2019,  employees were exposed to hazardous chemical products such as but not limited to Duracoat Pre-Catalyzed Flat 10 Sheen Gal, Klear Kote Clear Epoxy Hardener, Blue Ridge Products, Inc, Xpert Toner Base, Primer Sealer White, E-Z Vinyl Sealer Gal, #48 Lacquer Thinner, Methyl Ethyl Ketone. The employer did not maintain a list of hazardous chemical products used in the shop.
Recent events (2)
  • · I (S) $4579.6
  • · Z (S) $6630

1910.1200 F06

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 5, 2019
Abate by
Aug 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section:  Five Star Architectural, LLC, Dawsonville, GA - On or about 02/06/2019,  employees were exposed to hazardous chemical products such as but not limited to Duracoat Pre-Catalyzed Flat 10 Sheen Gal, Klear Kote Clear Epoxy Hardener, Blue Ridge Products, Inc, Xpert Toner Base, Primer Sealer White, E-Z Vinyl Sealer Gal, #48 Lacquer Thinner, Methyl Ethyl Ketone. The secondary containers such as but not limited to the ones located in the paint area, were not properly labeled.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 G08

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s):  Five Star Architectural, LLC, Dawsonville, GA - On or about 02/06/2019,  employees were exposed to hazardous chemical products such as but not limited to Duracoat Pre-Catalyzed Flat 10 Sheen Gal, Klear Kote Clear Epoxy Hardener, Blue Ridge Products, Inc, Xpert Toner Base, Primer Sealer White, E-Z Vinyl Sealer Gal, #48 Lacquer Thinner, Methyl Ethyl Ketone. Safety data sheets were not maintained and readily accessible to employees, as required by the hazard communication standard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 5, 2019
Abate by
Aug 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  Five Star Architectural, LLC, Dawsonville, GA - On or about 02/06/2019, employees were exposed to hazardous chemical products such as but not limited to Duracoat Pre-Catalyzed Flat 10 Sheen Gal, Klear Kote Clear Epoxy Hardener, Blue Ridge Products, Inc, Xpert Toner Base, Primer Sealer White, E-Z Vinyl Sealer Gal, #48 Lacquer Thinner, Methyl Ethyl Ketone. Information and training on the specific hazards of the chemicals and their proper use, storage, and handling were not provided.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Five Star Architectural, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343770608.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.