OSHA Inspection: THE JONES METAL PRODUCTS COMPANY

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of THE JONES METAL PRODUCTS COMPANY in 200 NORTH CENTER STREET, WEST LAFAYETTE, OH 43845 (NAICS 332116). OSHA activity number 343771036.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Jones Metal Products Company — free Get an email when a new federal OSHA severe-injury report for The Jones Metal Products Company is published. One employer, no account, unsubscribe in one click.
Site address
200 NORTH CENTER STREET
City
WEST LAFAYETTE
State
OH
ZIP
43845
Mailing
200 NORTH CENTER STREET, WEST LAFAYETTE, OH 43845
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
62
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II

Other-than-serious 1 instance 6 exposed
Issued
Jun 6, 2019
Abate by
Jun 26, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:  a. On or about February 1, 2019, located in the Stamping Department, employees performed service and maintenance activities, including inspections, lubrication, cleaning, die adjustments and die changes, on mechanical power press #29. The employer's specific lockout/tagout procedures did not include a specific statement of the intended use of the procedure; the specific rules and techniques for shutting down, isolating and blocking/securing the press; specific procedural steps for placement and removal of lockout/tagout devices and the responsibility of each. The procedure did not include specific requirements to test the press to determine and verify the effectiveness of lockout devices.
Recent events (1)
  • — Z (O) $0

1910.147 C06 I C

Other-than-serious 1 instance 6 exposed
Issued
Jun 6, 2019
Abate by
Jun 26, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i)(C): Where lockout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected.  a. On or about February 8, 2019, located in the Stamping Department, the employer did not ensure there was a review of the energy control procedures between the inspector and each employee for Press #29 and Press number #007.
Recent events (1)
  • — Z (O) $0

View The Jones Metal Products Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343771036.