WASHINGTON, DC —
OSHA Inspection: K & C FRAMING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of K & C FRAMING, INC. in 1923 9TH STREET NW, WASHINGTON, DC 20008 (NAICS 238130). OSHA activity number 343773800.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- K & C FRAMING, INC.
- Site address
- 1923 9TH STREET NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20008
- Mailing
- 6401 STREAM VALLEY WAY, GAITHERSBURG, MD 20882
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 20
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.102 A01
- Issued
- Jun 21, 2019
- Abate by
- Jun 27, 2019
- Penalty
- Initial $3,864 · Current $3,864
General-duty citation text
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) On or about February 8, 2019; fifth floor; employees were not wearing eye protection while utilizing pneumatic nail guns and hammers. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $3864
- — Z (S) $3864
1926.501 B13
- Issued
- Jun 21, 2019
- Abate by
- Jun 27, 2019
- Penalty
- Initial $5,304 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about February 8, 2019, fifth floor area; employees were observed working on a residential roof without fall protection in place to protect them from falling an estimated 50 feet to ground level or 10-feet to the interior floor. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $3000
- — Z (S) $5304
1926.701 B
- Issued
- Jun 21, 2019
- Abate by
- Jul 3, 2019
- Penalty
- Initial $5,304 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement: a) On or about February 8, 2019; fifth floor; employees were working near uncapped rebar exposing them to a potential impalement hazard while installing the trusses. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $3000
- — Z (S) $5304
1926.1053 B01
- Issued
- Jun 21, 2019
- Abate by
- Jun 28, 2019
- Penalty
- Initial $3,864 · Current $1,136 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about February 8, 2019, fifth floor area; employees were using a 6-foot step-ladder to access the top-plate and the side rails did not extended 3-feet above the surface, exposing employees to an estimated 10-foot fall to the wooden deck. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1136
- — Z (S) $3864
1926.1053 B04
- Issued
- Jun 21, 2019
- Abate by
- Jun 28, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about February 8, 2019; fifth floor area of the residential home; employees were using a six-foot step ladder in the closed position, which is designed to be used in the open position, to access the top-plate area. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B13
- Issued
- Jun 21, 2019
- Abate by
- Jun 28, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On or about February 8, 2019; fifth floor; employees were using the top step of a six foot step ladder to access the top-plate area that was too short for the application; flush to working platform. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.41 A02
- Issued
- Jun 21, 2019
- Abate by
- Jun 27, 2019
- Penalty
- Initial $644 · Current $0 Reduced
General-duty citation text
29 CFR 1904.41(a)(2): The employer did not electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee by the date listed in paragraph (c) of this section of the year after the calendar year covered by the form: a) On or about February 8, 2019; Located at 1923 9th Street NW: the employer failed to electronically submit information from their OSHA Form 300A or equivalent for calendar year 2018 by March 2, 2019. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $644
More inspections at K & C Framing, INC.
View K & C Framing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343773800.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.