Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DURA-BOND STEEL CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DURA-BOND STEEL CORPORATION in 2658 PUCKETY STREET, EXPORT, PA 15632 (NAICS 332312). OSHA activity number 343775516.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dura-Bond Steel Corporation — free Get an email when a new federal OSHA severe-injury report for Dura-Bond Steel Corporation is published. One employer, no account, unsubscribe in one click.
Site address
2658 PUCKETY STREET
City
EXPORT
State
PA
ZIP
15632
Mailing
5790 KENNEDY AVENUE, EXPORT, PA 15632
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
75
Ownership type
A

2 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 19, 2019
Abate by
Mar 15, 2019
Penalty
Initial $4,831 · Current $3,140 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a) Facility, 2658 Puckety Street, Export, PA:  On or about February 11, 2019 the employer had not conducted a periodic inspection of an energy control procedure to ensure the procedure was adequate and met the requirements of the standard.  The employer's inspection protocol consisted of an employee looking at the list of equipment that had multiple energy sources and telling them if anything had been updated; the employee did not take a procedure and follow it to ensure the steps adequately controlled all energy sources for the item being serviced.
Recent events (2)
  • — I (S) $3140.15
  • — Z (S) $4831

1910.147 C07 I A

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 19, 2019
Abate by
Mar 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  (a) Facility, 2658 Puckety Street, Export, PA:  On or about February 11, 2019 authorized persons who perform servicing and maintenance on equipment had not been trained on or shown the specific energy control procedures to ensure they were aware of energy sources, type and magnitude and methods necessary to isolate such sources.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Dura-Bond Steel Corporation's full OSHA safety record →