Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CONWED PLASTICS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CONWED PLASTICS, LLC in 1755 OLYMPIC DRIVE, ATHENS, GA 30601 (NAICS 326199). OSHA activity number 343782637.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Conwed Plastics, LLC — free Get an email when a new federal OSHA severe-injury report for Conwed Plastics, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1755 OLYMPIC DRIVE
City
ATHENS
State
GA
ZIP
30601
Mailing
1755 OLYMPIC DRIVE, ATHENS, GA 30601
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
75
Ownership type
A

5 citations on file for this inspection.

1910.147 D04 I

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Mar 7, 2019
Abate by
Apr 2, 2019
Penalty
Initial $13,260 · Current $0 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees.   On 2/11/19, in the production area, authorized employees did not affix a lockout device as they entered into a hazard area of the Winder during setup of the machine and were exposed to crushing hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13260

1910.147 C06 I

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Mar 7, 2019
Abate by
Apr 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.  On 2/11/19, at the Athens facility, the employer did not ensure the periodic inspection corrected deficiencies found in the specific written procedures. On Extruder 9 Die Heater Bands and Extruder 9 Extruder procedures heat energy was not listed as an energy on the specific written procedure (400-450 degrees).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I C

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 7, 2019
Abate by
Apr 23, 2019
Penalty
Initial $0 · Current $5,240
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected.     On 2/11/19, at the Athens facility, the employer did not ensure all Authorized employees were included in the periodic inspection of the established Lockout program and instead the review took place between the same 2 employees for the past 6 years.  Additionally, thermal energy sources were missing from the Lockout/tagout procedures. Employees can be protected from the thermal energy sources by the use of Personal Protective Equipment.
Recent events (2)
  • — I (S) $5240
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 7, 2019
Abate by
Oct 1, 2019
Penalty
Initial $5,683 · Current $13,260
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.    On 2/11/19, at the Orienter core handler/inserter, employees were exposed to pinch points as the machine was not guarded.
Recent events (2)
  • — I (S) $13260
  • — Z (S) $5683

1910.219 C02 I

Serious Gravity 10 1 instance 10 exposed
Issued
Mar 7, 2019
Abate by
Oct 1, 2019
Penalty
Initial $13,260 · Current $0 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting.    On 2/11/19, in the production area, horizontal shafting was not guarded. Instance include:    a - Extruder winder shafts (30-40 FPM)  b - Orienter 2 shafts (1100-1200FRM)
Recent events (2)
  • — I (S) $0
  • — Z (S) $13260

View Conwed Plastics, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343782637.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.