OSHA Inspection: CORE PRODUCTS INTERNATIONAL, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CORE PRODUCTS INTERNATIONAL, INC. in 1505 PARKER DRIVE, CHETEK, WI 54728 (NAICS 339113). OSHA activity number 343788501.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Core Products International, INC. — free Get an email when a new federal OSHA severe-injury report for Core Products International, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1505 PARKER DRIVE
City
CHETEK
State
WI
ZIP
54728
Mailing
808 PROSPECT AVENUE, OSCEOLA, WI 54020
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339113
Employees
77
Ownership type
A

10 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 6 exposed
Issued
May 6, 2019
Abate by
Aug 23, 2019
Penalty
Initial $11,934 · Current $8,354 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a) Cutting department; Energy isolation procedures were not documented.
Recent events (2)
  • — I (S) $8353.8
  • — Z (S) $11934

1910.147 C07 I A

Serious Gravity 10 1 instance 6 exposed
Issued
May 6, 2019
Abate by
Aug 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:    (a) Cutting department; Authorized level lockout training was not provided for workers who perform lockout covered activities, including but not limited to; setup and blade change operations on strip cutters.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D03

Serious Gravity 10 1 instance 2 exposed
Issued
May 6, 2019
Abate by
Aug 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):    (a) Cutting department; Electrical and pneumatic sources of energy were not isolated on strip cutting machines during setup and roll changing operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 10 2 instances 5 exposed
Issued
May 6, 2019
Abate by
Aug 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    (a) Cutting department; Lockout devices are not affixed to isolation points for electrical and pneumatic energy on strip cutting machines during setup and roll changing operations.    (b) Cutting department; Lockout devices are not affixed to isolation points for pneumatic energy on strip cutting machines during blade change operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 2 instances 6 exposed
Issued
May 6, 2019
Abate by
May 20, 2019
Penalty
Initial $11,934 · Current $8,354 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Cutting department; Guarding was not provided for ingoing nip points between powered feed rollers on the infeed side of strip cutting machines, including but not limited to; Asset. Numbers 655, 931, and 932.    (b) Cutting department; Guarding was not provided for pinch points between the knife holder and upper frame on the infeed side of strip cutting machines, including but not limited to; Asset. Numbers 655, 933, 931, and 932.
Recent events (2)
  • — I (S) $8353.8
  • — Z (S) $11934

1910.212 A03 II

Serious Gravity 10 1 instance 6 exposed
Issued
May 6, 2019
Abate by
May 20, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  (a) Cutting department; Point of operation guarding was not provided for the cutting knife on strip cutting machines, including but not limited to; Asset. Numbers 655, 933, 931, and 932. On or about February 5, 2019, An amputation injury occurred in the point of operation, on the outfeed side of a TRC 1000 VS strip cutting machine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 1 1 instance 6 exposed
Issued
May 6, 2019
Abate by
May 20, 2019
Penalty
Initial $5,115 · Current $3,581 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:    (a) Cutting department; Protection was not provided for energized 120 volt conductors on a TRC brand VS 1000 strip cutter (Asset. 931) by enclosure or elevation.
Recent events (2)
  • — I (S) $3580.5
  • — Z (S) $5115

1904.32 B02 II

Other-than-serious 1 instance 77 exposed
Issued
May 6, 2019
Abate by
May 20, 2019
Penalty
Initial $1,706 · Current $1,195 Reduced
29 CFR 1904.32(b)(2)(ii): The employer did not complete on the annual summary, the calendar year covered, the company's name, establishment name, establishment address, annual average number of employees covered by the OSHA 300 Log, and the total hours worked by all employees covered by the OSHA 300 Log:    (a) Throughout the Chetek, WI facility; On February 14, 2019, The employer's annual summary of injuries and illnesses (OSHA Form 300A) for calendar year 2018 was not completely filled out.
Recent events (2)
  • — I (O) $1194.9
  • — Z (O) $1706

1904.40 A

Deleted Other-than-serious 1 instance 77 exposed
Issued
May 6, 2019
Abate by
May 20, 2019
Penalty
Initial $1,706 · Current $0 Reduced
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours:  (a) Throughout the Chetek, WI facility; On February 14, 2019, The employer did not provide their injury and illness log (OSHA Form 300) for calendar year 2019.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1706

1910.1030 C01 I

Other-than-serious 1 instance 4 exposed
Issued
May 6, 2019
Abate by
Aug 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(c)(1)(i): The employer having employee(s) with occupational exposure did not establish a written Exposure Control Plan designed to eliminate or minimize employee exposure:    (a) Throughout the Chetek, WI facility; On or about February 5, 2019, a written Exposure Control Plan was not developed and implemented before designated employees rendered first aid and cleaned up blood related to an amputation injury that occurred.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Core Products International, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343788501.