Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MANUEL CRUZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MANUEL CRUZ in BUILDING 12 LEESLAND DRIVE, WESTERVILLE, OH 43081 (NAICS 238130). OSHA activity number 343794558.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Manuel Cruz — free Get an email when a new federal OSHA severe-injury report for Manuel Cruz is published. One employer, no account, unsubscribe in one click.
Establishment
MANUEL CRUZ
Site address
BUILDING 12 LEESLAND DRIVE
City
WESTERVILLE
State
OH
ZIP
43081
Mailing
3877 HOOVER ROAD, GROVE CITY, OH 43123
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 1 instance 6 exposed
Issued
Feb 27, 2019
Abate by
Mar 19, 2019
Penalty
Initial $2,842 · Current $2,842
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.   a. On or about February 19, 2019, located at Building 12 at the Village at Central College, the employer did not instruct employees in the recognition and avoidance of unsafe conditions and the regulations applicable to framing work when employees were working from heights, operating nail guns, climbing ladders, working around equipment, etc., thereby exposing employees to fall, struck-by and caught-in/between hazards.
Recent events (1)
  • — Z (S) $2842

1926.501 B13

Serious Gravity 10 3 instances 6 exposed
Issued
Feb 27, 2019
Abate by
Mar 11, 2019
Penalty
Initial $3,978 · Current $3,978
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.   a. On or about February 19, 2019, located at Building 12 at the Village at Central College, an employee was standing on the second story wall top plate without any means of fall protection, thereby exposing the employee to a fall hazard of approximately 20 feet.      b. On or about February 19, 2019, located at Building 12 at the Village at Central College, employees were performing framing work on a residential home while not all windows had a top rail, thereby exposing the employees to a fall hazard of approximately 12 feet.      c. On or about February 19, 2019, located at Building 12 at the Village at Central College, employees were performing framing work on a residential home while there was a six foot by six foot floor hole behind the stairs exposing the employees to a fall hazard of approximately 10 feet.
Recent events (1)
  • — Z (S) $3978

1926.600 A03 II

Serious Gravity 10 1 instance 6 exposed
Issued
Feb 27, 2019
Abate by
Mar 19, 2019
Penalty
Initial $3,978 · Current $3,978
29 CFR 1926.600(a)(3)(ii): Whenever the equipment is parked, the parking brake shall be set. Equipment parked on inclines shall have the wheels chocked and the parking brake set.   a. On or about February 19, 2019, located at Building 12 at the Village at Central College, a JCB 506-C rough-terrain forklift was used to lift building materials to the roof of a residential home. The forklift was parked on an incline without the wheels being chocked and with a 2 x 4 board used to hold pressure onto the forklifts brake due to the parking brake being inoperable, thereby exposing the employees to a struck-by and/or caught-between hazard if a runaway condition occurred with the forklift.
Recent events (1)
  • — Z (S) $3978

1926.602 C01 VI

Serious Gravity 10 1 instance 6 exposed
Issued
Feb 27, 2019
Abate by
Mar 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.602(c)(1)(vi): All industrial trucks in use shall meet the applicable requirements of design, construction, stability, inspection, testing, maintenance, and operation, as defined in American National Standards Institute B56.1-1969, Safety Standards for Powered Industrial Trucks.   a. On or about February 19, 2019, located at Building 12 at the Village at Central College, a JCB 506-C rough-terrain forklift was used to lift building materials to the roof of a residential home. The forklift was left unattended with the load elevated, thereby exposing the employees to a struck-by/caught-in hazard. The employer failed to comply with the requirements of operations under ANSI B56.1, which read, When leaving a powered industrial truck unattended, load engaging means shall be fully lowered, controls shall be neutralized, power shut off, brakes set, key or connector plug removed. Block wheels if truck is parked on an incline.
Recent events (1)
  • — Z (S) $0

1926.1051 B

Serious Gravity 10 1 instance 6 exposed
Issued
Feb 27, 2019
Abate by
Mar 19, 2019
Penalty
Initial $3,978 · Current $3,978
29 CFR 1926.1051(b): Employers shall provide and install all stairway and ladder fall protection systems required by this subpart and shall comply with all other pertinent requirements of this subpart before employees begin the work that necessitates the installation and use of stairways, ladders, and their respective fall protection systems.  a. On or about February 19, 2019, located at Building 12 at the Village at Central College, employees used stairs to gain access to and from the second floor of a residential home. The employees had no fall protection system, i.e. guardrails on each side of the stairs exposing the employees to a maximum fall hazard of 16 feet.
Recent events (1)
  • — Z (S) $3978

1926.600 A05

Other-than-serious 1 instance 6 exposed
Issued
Feb 27, 2019
Abate by
Mar 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.600(a)(5): All cab glass shall be safety glass, or equivalent, that introduces no visible distortion affecting the safe operation of any machine covered by this subpart.  a. On or about February 19, 2019, located at Building 12 at the Village at Central College, a JCB 506-C rough-terrain forklift was used to lift building materials to the roof of a residential home. The employer did not ensure that the forklifts cab glass was free of visible distortions as the right side window and left back window was cracked in several areas that could affect the safe operation of the forklift.
Recent events (1)
  • — Z (O) $0

View Manuel Cruz's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343794558.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.