DENVER, CO ·
OSHA Inspection: FUTURE FOAM INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of FUTURE FOAM INC. in 11475 E 40TH AVE, DENVER, CO 80239 (NAICS 326150). OSHA activity number 343797080.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FUTURE FOAM INC.
- Site address
- 11475 E 40TH AVE
- City
- DENVER
- State
- CO
- ZIP
- 80239
- Mailing
- 11475 E 40TH AVE, DENVER, CO 80239
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326150
- Employees
- 50
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.37 B04
- Issued
- Apr 30, 2019
- Penalty
- Initial $3,623 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: (a) Future Foam Inc., at 11475 E. 40th Ave Denver, CO: On and preceding 2/20/19, the employer did not ensure that signs were posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent. Employees performed functions on the east side of the warehouse, including using a conveyor to move material, including polyurethane foam. This area was also used to store large pieces of polyurethane foam. Exit route signs were not visible in this area. The direction to the nearest exit was not apparent. This condition exposed employees to a fire hazard.
Recent events (2)
- · I (S) $2100
- · Z (S) $3623
1910.212 A03 II
- Issued
- Apr 30, 2019
- Abate by
- Jun 3, 2019
- Penalty
- Initial $7,104 · Current $4,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Future Foam Inc., at 11475 E. 40th Ave Denver, CO: On and preceding 2/20/19, the employer did not ensure point(s) of operation of machinery were guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s). Employees operated vertical band saws to cut pieces of polyurethane foam. The Edge-Sweets model E2 vertical band saw blade was not guarded in a manner that prevented the operator's hand from being in the path of the saw blade. This condition exposed the operator to an amputation hazard. (b) Future Foam Inc., at 11475 E. 40th Ave Denver, CO: On and preceding 2/20/19, the employer did not ensure point(s) of operation of machinery were guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s). Employees operated vertical band saws to cut pieces of polyurethane foam. The Edge-Sweets model EL-3 vertical band saw blade was not guarded in a manner that prevented the operator's hand from being in the path of the saw blade. This condition exposed the operator to an amputation hazard. (c) Future Foam Inc., at 11475 E. 40th Ave Denver, CO: On and preceding 2/20/19, the employer did not ensure point(s) of operation of machinery were guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s). Employees operated a Central Machinery 13" drill press, located in the Maintenance Shop. The drill press was not guarded in a manner that prevented the operator's hand from being in the path of the drill bit. This condition exposed the operator to an amputation hazard.
Recent events (2)
- · I (S) $4400
- · Z (S) $7104
1910.212 B
- Issued
- Apr 30, 2019
- Abate by
- Jun 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) Future Foam Inc., at 11475 E. 40th Ave Denver, CO: On and preceding 2/20/19, machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving. Employees operated a Central Machinery 13 inch drill press, located in the Maintenance Shop. The drill press was designed for a fixed location. The drill press was not secured to the Maintenance Shop floor. This condition exposed employees to a struck-by hazard. (b) Future Foam Inc., at 11475 E. 40th Ave Denver, CO: On and preceding 2/20/19, machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving. Employees operated a 20 ton hydraulic press, located in the Maintenance Shop. The hydraulic press was designed for a fixed location. The hydraulic press was not secured to the Maintenance Shop floor. This condition exposed employees to a struck-by hazard.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.146 C07 III
- Issued
- Apr 30, 2019
- Abate by
- Jun 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(7)(iii): The employer did not document the basis for determining that all hazards in a permit space had been eliminated, through a written certification that contained the date, the location of the space, and the signature of the person: (a) Future Foam Inc., at 11475 E. 40th Ave Denver, CO: On and preceding 2/20/19, the employer did not document the basis for determining that all hazards in a permit space had been eliminated, through a written certification that contained the date, the location of the space, and the signature of the person. Employees performed maintenance of a hydraulic baler, by entering the space containing the hydraulic ram. This space was a Permit Required Confined Space. The employer had reclassified the permit space as a non-permit space. The employer did not certify that all hazards in the permit space had been eliminated. This condition potentially exposed employees to confined space hazards.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Future Foam INC.
View Future Foam INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326150)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343797080.