Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RISE RESIDENTIAL CONSTRUCTION, L.P.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RISE RESIDENTIAL CONSTRUCTION, L.P. in 705 AVE. B, GARLAND, TX 75045 (NAICS 236220). OSHA activity number 343801148.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rise Residential Construction, L.P. — free Get an email when a new federal OSHA severe-injury report for Rise Residential Construction, L.P. is published. One employer, no account, unsubscribe in one click.
Site address
705 AVE. B
City
GARLAND
State
TX
ZIP
75045
Mailing
16812 DALLAS PKWY., DALLAS, TX 75248
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
2
Ownership type
A

6 citations on file for this inspection.

1926.152 I06

Other-than-serious 1 instance 3 exposed
Issued
Mar 22, 2019
Abate by
Apr 17, 2019
Penalty
Initial $5,834 · Current $5,834
29 CFR 1926.152(i)(6): In locations where flammable vapors could have been present, precautions were not taken to prevent ignition by eliminating or controlling sources of ignition:    (a) Employees at the site were exposed to fire hazards when containers of gasoline were stored in the utility room beneath electrical breaker panels were which were not dead front.
Recent events (2)
  • — I (O) $5834
  • — Z (S) $5834

1926.403 B01

Other-than-serious 1 instance 3 exposed
Issued
Mar 22, 2019
Abate by
Apr 17, 2019
Penalty
Initial $5,834 · Current $5,834
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:    (a)  Employees at the site were exposed to electrical shock hazards when dead fronts were not installed on two electrical breaker panels and panel doors were open.
Recent events (2)
  • — I (O) $5834
  • — Z (S) $5834

1926.405 G01 III B

Other-than-serious 1 instance 3 exposed
Issued
Mar 22, 2019
Abate by
Apr 17, 2019
Penalty
Initial $5,834 · Current $5,834
29 CFR 1926.405(g)(1)(iii)(B): 29 CFR 1926.405(g)(1)(iii)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors:    (a) Employees at the site were exposed to electrical shock hazards when electrical cables were ran through a hole in the wall in the utility room.
Recent events (2)
  • — I (O) $5834
  • — Z (S) $5834

1926.451 E01

Serious Gravity 10 1 instance 6 exposed
Issued
Mar 22, 2019
Abate by
Apr 17, 2019
Penalty
Initial $5,834 · Current $4,375 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.    Employees at the site were exposed to fall hazards greater than 6 ft. while accessing a scaffold assembly which did not have a ladder installed.
Recent events (2)
  • — I (S) $4375
  • — Z (S) $5834

1926.452 C02

Serious Gravity 10 1 instance 19 exposed
Issued
Mar 22, 2019
Abate by
Apr 17, 2019
Penalty
Initial $5,834 · Current $0 Reduced
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:    (a) Employees at the site were exposed to fall hazards greater than 10 ft. while working from a scaffold assembly which was not completely braced.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5834

1926.451 G01

Serious Gravity 10 1 instance 6 exposed
Issued
Mar 22, 2019
Abate by
Apr 17, 2019
Penalty
Initial $5,834 · Current $4,375 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    (a) Employees at the site were exposed to fall hazards greater than 10 ft. while working from scaffolding without any form of fall protection.
Recent events (2)
  • — I (S) $4375
  • — Z (S) $5834

View Rise Residential Construction, L.P.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343801148.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.