Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE WESTIN ST. JOHN RESORT & VILLAS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE WESTIN ST. JOHN RESORT & VILLAS in 300-A CHOCOLATE HOLE, ST JOHN, VI 00831 (NAICS 721110). OSHA activity number 343802385.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Westin ST. John Resort & Villas — free Get an email when a new federal OSHA severe-injury report for The Westin ST. John Resort & Villas is published. One employer, no account, unsubscribe in one click.
Site address
300-A CHOCOLATE HOLE
City
ST JOHN
State
VI
ZIP
00831
Mailing
PO BOX 8310, ST JOHN, VI 00831
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
163
Ownership type
A

4 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 11, 2019
Penalty
Initial $5,797 · Current $4,348 Reduced
29 CFR 1910.151(c):  Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use [ANSIZ358.1-2014]:   a. On or about February 21, 2019, at the laundry area. An operational emergency eye wash station was not provided in the immediate area when employees used and/or handled corrosive Ecolab/Eco-Star laundry products such as:  Sour Control (phosphoric acid), Oxy-Brite (hydrogen peroxide), Eco-Star Builder C (sodium hydroxide), and sodium hypochlorite solution.   NOTE: Certification of abatement is not required for this citation item since it was submitted prior to citation issuance.
Recent events (2)
  • — I (S) $4347.75
  • — Z (S) $5797

1910.178 L04 III

Serious Gravity 1 3 instances 3 exposed
Issued
Jun 11, 2019
Abate by
Jul 1, 2019
Penalty
Initial $4,347 · Current $3,260 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  a.   On or about February 21, 2019, at the purchasing and engineering department areas, employees were exposed to a struck by hazard, while loading and unloading materials on a Clark CMP 25L propane (LPG) and JCB 505-20TC fuel forklifts. The forklift operators performance evaluations were not conducted every three years.   NOTE:  Certification of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $3260.25
  • — Z (S) $4347

1910.178 Q07

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 11, 2019
Penalty
Initial $7,246 · Current $5,435 Reduced
29 CFR 1910.178(q)(7): Industrial trucks were being placed in service after the examination showed condition(s) adversely affecting the safety of the vehicle:  a.   On or about February 21, 2019, at the purchasing department area, employees were exposed to a struck by hazard, while loading and unloading materials with a Clark CMP 25L propane (LPG) forklift where the back-up alarm  was not operational.   NOTE:  Certification of abatement is not required for this citation item since it was submitted prior to citation issuance.
Recent events (2)
  • — I (S) $5434.5
  • — Z (S) $7246

1910.305 C04

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 11, 2019
Penalty
Initial $7,246 · Current $5,435 Reduced
29 CFR 1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface:  a. On or about February 21, 2019, at the Bamboula kitchen area, employees are exposed to an electric shock from an exhaust fan switch with exposed conductors that did not have a face plate cover.   NOTE: Certification of abatement is not required for this citation item since it was submitted prior to citation issuance.
Recent events (2)
  • — I (S) $5434.5
  • — Z (S) $7246

View The Westin ST. John Resort & Villas's full OSHA safety record →