LEWES, DE —
OSHA Inspection: COAM EXTERIOR, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COAM EXTERIOR, INC in 31611 EXETER WAY, LEWES, DE 19958 (NAICS 238170). OSHA activity number 343814083.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COAM EXTERIOR, INC
- Site address
- 31611 EXETER WAY
- City
- LEWES
- State
- DE
- ZIP
- 19958
- Mailing
- 26826 LEWES-GEORGETOWN BLVD, LEWES, DE 19958
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.451 B05 I
- Issued
- Aug 5, 2019
- Abate by
- Aug 29, 2019
- Penalty
- Initial $4,376 · Current $3,063 Reduced
General-duty citation text
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length, extended over its support more than 12 inches: Note: Does not apply if the platform was designed and installed so that the cantilevered portion of the platform was able to support employees and/or materials without tipping or had guardrails that blocked employee access to the end. a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that ends of work platforms on a pump jack scaffold did not extend more than 12 inches over the support, exposing employees to fall hazards approximately 12 feet above grade.
Recent events (2)
- — I (S) $3063.2
- — Z (S) $4376
1926.451 B07
- Issued
- Aug 5, 2019
- Abate by
- Aug 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(7): On scaffolds where platforms were overlapped to create a long platform, the overlap did not occur only over supports, and/or was less than 12 inches (30 cm) when the platforms were not nailed together or otherwise restrained to prevent movement. a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that overlapped platforms on a pump jack scaffold occurred over the support and/or the overlap was at least 12 inches or nailed together.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02
- Issued
- Aug 5, 2019
- Abate by
- Aug 29, 2019
- Penalty
- Initial $4,376 · Current $3,063 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that a supported pump-jack scaffold was erected on firm foundation. Employees were exposed to fall hazards while working at heights of approximately 12 foot above grade on a scaffold erected on compacted dirt ground without the use of base-plates or mudsills.
Recent events (2)
- — I (S) $3063.2
- — Z (S) $4376
1926.451 F03
- Issued
- Aug 5, 2019
- Abate by
- Aug 29, 2019
- Penalty
- Initial $4,376 · Current $3,063 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that the pump jack scaffold was inspected for visible defects by a competent person before the work shift. Employees were exposed to fall hazards while working at heights of approximately 12 foot above grade on a pump jack scaffold with deficiencies, including a lack of guardrails, improper overlapping of platforms, missing base plates and mud sills, and not properly braced at the top and bottom.
Recent events (2)
- — I (S) $3063.2
- — Z (S) $4376
1926.451 G04 I
- Issued
- Aug 5, 2019
- Abate by
- Aug 29, 2019
- Penalty
- Initial $4,376 · Current $3,063 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that guardrails were installed along all open sides of platforms of a pump jack scaffold. Where a top rail was installed, a mid-rail and bottom rail were not installed, exposing employees to fall hazards approximately 12 feet above grade. b) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that guardrails were installed along all ends of platforms of a pump jack scaffold. A guardrail was not installed on the end of a work platform, exposing employees to fall hazards approximately 12 feet above grade.
Recent events (2)
- — I (S) $3063.2
- — Z (S) $4376
1926.451 G01 VII
- Issued
- Aug 5, 2019
- Abate by
- Aug 29, 2019
- Penalty
- Initial $8,752 · Current $6,126 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that employees working on a pump-jack scaffold were protected from falls. Employees were exposed to fall hazards while working at heights of approximately 12 foot above grade on a scaffold on which guardrails were not installed nor were employees protected by conventional means of fall protection. Coam Exterior, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.451 (g)(1)(vii), which was contained in OSHA inspection number 10149901, citation number 1, item number 1a and was affirmed as a final order on April 21, 2015, with respect to a workplace located at Lot 134 Parkshore, Middletown, Delaware 19709.
Recent events (2)
- — I (R) $6126.4
- — Z (R) $8752
1926.452 J02
- Issued
- Aug 5, 2019
- Abate by
- Aug 29, 2019
- Penalty
- Initial $6,252 · Current $4,376 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that the poles of a pump-jack scaffold were secured to the structure at the top and bottom. Employees were exposed to fall hazards while working at heights of approximately 12 foot above grade from a pump-jack scaffold on which rigid triangular bracing was not installed at the bottom of the poles. Coam Exterior, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard ,29 CFR 1926.452(j)(2), which was contained in OSHA inspection number 1014990 citation number 1, item number 1b and was affirmed as a final order on April 21, 2015, with respect to a workplace located at Lot 134 Parkshore, Middletown, Delaware, 19709.
Recent events (2)
- — I (R) $4376.4
- — Z (R) $6252
1926.454 A
- Issued
- Aug 5, 2019
- Abate by
- Aug 29, 2019
- Penalty
- Initial $6,252 · Current $4,376 Reduced
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that employees were trained to recognize the hazards associated with working on a pump jack scaffold and the procedures to control or minimize the hazards. Employees were exposed to fall hazards while working at heights of approximately 12 foot above grade on a pump jack scaffold with deficiencies, including a lack of guardrails, improper overlapping of platforms, missing base plates and mud sills, and not properly braced at the top and bottom. Coam Exterior, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard (name previously cited standard), which was contained in OSHA inspection number1014990 citation number 1, item number (1) (c) and was affirmed as a final order on April 21, 2015, with respect to a workplace located at Lot 134,Parkside Development, Middletown, DE.
Recent events (2)
- — I (R) $4376.4
- — Z (R) $6252
More inspections at Coam Exterior, INC