Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COAM EXTERIOR, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COAM EXTERIOR, INC in 31611 EXETER WAY, LEWES, DE 19958 (NAICS 238170). OSHA activity number 343814083.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coam Exterior, INC — free Get an email when a new federal OSHA severe-injury report for Coam Exterior, INC is published. One employer, no account, unsubscribe in one click.
Establishment
COAM EXTERIOR, INC
Site address
31611 EXETER WAY
City
LEWES
State
DE
ZIP
19958
Mailing
26826 LEWES-GEORGETOWN BLVD, LEWES, DE 19958
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

8 citations on file for this inspection.

1926.451 B05 I

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 5, 2019
Abate by
Aug 29, 2019
Penalty
Initial $4,376 · Current $3,063 Reduced
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length, extended over its support more than 12 inches:  Note:  Does not apply if the platform was designed and installed so that the cantilevered portion of the platform was able to support employees and/or materials without tipping or had guardrails that blocked employee access to the end.    a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that ends of work platforms on a pump jack scaffold did not extend more than 12 inches over the support, exposing employees to fall hazards approximately 12 feet above grade.
Recent events (2)
  • — I (S) $3063.2
  • — Z (S) $4376

1926.451 B07

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 5, 2019
Abate by
Aug 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(7): On scaffolds where platforms were overlapped to create a long platform, the overlap did not occur only over supports, and/or was less than 12 inches (30 cm) when the platforms were not nailed together or otherwise restrained to prevent movement.  a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that overlapped platforms on a pump jack scaffold occurred over the support and/or the overlap was at least 12 inches or nailed together.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 5, 2019
Abate by
Aug 29, 2019
Penalty
Initial $4,376 · Current $3,063 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:    a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that a supported pump-jack scaffold was erected on firm foundation.  Employees were exposed to fall hazards while working at heights of approximately 12 foot above grade on a scaffold erected on compacted dirt ground without the use of base-plates or mudsills.
Recent events (2)
  • — I (S) $3063.2
  • — Z (S) $4376

1926.451 F03

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 5, 2019
Abate by
Aug 29, 2019
Penalty
Initial $4,376 · Current $3,063 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that the pump jack scaffold was inspected for visible defects by a competent person before the work shift.  Employees were exposed to fall hazards while working at heights of approximately 12 foot above grade on a pump jack scaffold with deficiencies, including a lack of guardrails, improper overlapping of platforms, missing base plates and mud sills, and not properly braced at the top and bottom.
Recent events (2)
  • — I (S) $3063.2
  • — Z (S) $4376

1926.451 G04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 5, 2019
Abate by
Aug 29, 2019
Penalty
Initial $4,376 · Current $3,063 Reduced
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms.    a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that guardrails were installed along all open sides of platforms of a pump jack scaffold.  Where a top rail was installed, a mid-rail and bottom rail were not installed, exposing employees to fall hazards approximately 12 feet above grade.    b) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that guardrails were installed along all ends of platforms of a pump jack scaffold.  A guardrail was not installed on the end of a work platform, exposing employees to fall hazards approximately 12 feet above grade.
Recent events (2)
  • — I (S) $3063.2
  • — Z (S) $4376

1926.451 G01 VII

Repeat Gravity 10 1 instance 2 exposed
Issued
Aug 5, 2019
Abate by
Aug 29, 2019
Penalty
Initial $8,752 · Current $6,126 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that employees working on a pump-jack scaffold were protected from falls.  Employees were exposed to fall hazards while working at heights of approximately 12 foot above grade on a scaffold on which guardrails were not installed nor were employees protected by conventional means of fall protection.    Coam Exterior, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.451 (g)(1)(vii), which was contained in OSHA inspection number 10149901, citation number 1, item number 1a and was affirmed as a final order on April 21, 2015, with respect to a workplace located at Lot 134 Parkshore, Middletown, Delaware 19709.
Recent events (2)
  • — I (R) $6126.4
  • — Z (R) $8752

1926.452 J02

Repeat Gravity 5 1 instance 3 exposed
Issued
Aug 5, 2019
Abate by
Aug 29, 2019
Penalty
Initial $6,252 · Current $4,376 Reduced
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.    a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that the poles of a pump-jack scaffold were secured to the structure at the top and bottom.  Employees were exposed to fall hazards while working at heights of approximately 12 foot above grade from a pump-jack scaffold on which rigid triangular bracing was not installed at the bottom of the poles.    Coam Exterior, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard ,29 CFR 1926.452(j)(2), which was contained in OSHA inspection number 1014990 citation number 1, item number 1b and was affirmed as a final order on April 21, 2015, with respect to a workplace located at Lot 134 Parkshore, Middletown, Delaware, 19709.
Recent events (2)
  • — I (R) $4376.4
  • — Z (R) $6252

1926.454 A

Repeat Gravity 5 1 instance 3 exposed
Issued
Aug 5, 2019
Abate by
Aug 29, 2019
Penalty
Initial $6,252 · Current $4,376 Reduced
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.    a) Costal Club, 31611 Exeter Way, Lewes, DE - On or about February 27, 2019, the employer failed to ensure that employees were trained to recognize the hazards associated with working on a pump jack scaffold and the procedures to control or minimize the hazards.  Employees were exposed to fall hazards while working at heights of approximately 12 foot above grade on a pump jack scaffold with deficiencies, including a lack of guardrails, improper overlapping of platforms, missing base plates and mud sills, and not properly braced at the top and bottom.    Coam Exterior, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard (name previously cited standard), which was contained in OSHA inspection number1014990 citation number 1, item number (1) (c) and was affirmed as a final order on April 21, 2015, with respect to a workplace located at Lot 134,Parkside Development, Middletown, DE.
Recent events (2)
  • — I (R) $4376.4
  • — Z (R) $6252

View Coam Exterior, INC's full OSHA safety record →