Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLUID POWER SUPPORT, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FLUID POWER SUPPORT, LLC in 22398 AUDRIAN RD. 9824, MEXICO, MO 65265 (NAICS 332312). OSHA activity number 343821906.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fluid Power Support, LLC — free Get an email when a new federal OSHA severe-injury report for Fluid Power Support, LLC is published. One employer, no account, unsubscribe in one click.
Site address
22398 AUDRIAN RD. 9824
City
MEXICO
State
MO
ZIP
65265
Mailing
22398 AUDRIAN RD. 9824, MEXICO, MO 65265
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
72
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 6, 2019
Abate by
Apr 22, 2019
Penalty
Initial $3,381 · Current $2,367 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section:  Energy control/lockout, specific procedures were not developed and written.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $2366.7
  • — Z (S) $3381

1910.147 C07 I A

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 6, 2019
Abate by
Apr 22, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  Employee(s) who performed work that was covered by the lockout standard, such as changing band saw blades and punch/dies on the ironworker, was not trained to lockout the machines.  Employee(s) were not trained on lockout work for an authorized employee.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D03

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 6, 2019
Abate by
Apr 22, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  A horizontal band saw and an ironworker were not locked out (energy isolated by a positive energy isolating devices, such as disconnects) during blade/tooling changes.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 6, 2019
Abate by
Apr 22, 2019
Penalty
Initial $3,381 · Current $2,367 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  A lockout/tagout annual inspection was not conducted, such as to determine who was performing maintenance work that required lockout/tagout and what equipment maintenance procedures required lockout, as well as ensuring lockout/tagout specific procedures were developed and written.  (Note: the annual inspection is required to be documented.)  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $2366.7
  • — Z (S) $3381

View Fluid Power Support, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343821906.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.