MEXICO, MO —
OSHA Inspection: FLUID POWER SUPPORT, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FLUID POWER SUPPORT, LLC in 22398 AUDRIAN RD. 9824, MEXICO, MO 65265 (NAICS 332312). OSHA activity number 343821906.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLUID POWER SUPPORT, LLC
- Site address
- 22398 AUDRIAN RD. 9824
- City
- MEXICO
- State
- MO
- ZIP
- 65265
- Mailing
- 22398 AUDRIAN RD. 9824, MEXICO, MO 65265
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 72
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II
- Issued
- Mar 6, 2019
- Abate by
- Apr 22, 2019
- Penalty
- Initial $3,381 · Current $2,367 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: Energy control/lockout, specific procedures were not developed and written. Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $2366.7
- — Z (S) $3381
1910.147 C07 I A
- Issued
- Mar 6, 2019
- Abate by
- Apr 22, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: Employee(s) who performed work that was covered by the lockout standard, such as changing band saw blades and punch/dies on the ironworker, was not trained to lockout the machines. Employee(s) were not trained on lockout work for an authorized employee. Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D03
- Issued
- Mar 6, 2019
- Abate by
- Apr 22, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): A horizontal band saw and an ironworker were not locked out (energy isolated by a positive energy isolating devices, such as disconnects) during blade/tooling changes. Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Mar 6, 2019
- Abate by
- Apr 22, 2019
- Penalty
- Initial $3,381 · Current $2,367 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: A lockout/tagout annual inspection was not conducted, such as to determine who was performing maintenance work that required lockout/tagout and what equipment maintenance procedures required lockout, as well as ensuring lockout/tagout specific procedures were developed and written. (Note: the annual inspection is required to be documented.) Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $2366.7
- — Z (S) $3381
More inspections at Fluid Power Support, LLC
View Fluid Power Support, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343821906.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.