Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,473Inspections Most recent open 2026-07-28 Last loaded 2026-07-31

OSHA Inspection: NATES BOATHOUSE & SEAFOOD EMPORIUM

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of NATES BOATHOUSE & SEAFOOD EMPORIUM in 1201 KING CROSS STREET, CHRISTIANSTED, VI 00820 (NAICS 722210). OSHA activity number 343832549.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nates Boathouse & Seafood Emporium — free Get an email when a new federal OSHA severe-injury report for Nates Boathouse & Seafood Emporium is published. One employer, no account, unsubscribe in one click.
Site address
1201 KING CROSS STREET
City
CHRISTIANSTED
State
VI
ZIP
00820
Mailing
1201 KING CROSS STREET, CHRISTIANSTED, VI 00820
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722210
Employees
32
Ownership type
A

2 citations on file for this inspection.

1910.36 G02

Serious Gravity 5 2 instances 5 exposed
Issued
Aug 15, 2019
Penalty
Initial $4,774 · Current $4,774
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  On or about March 7, 2019, at Nates Boathouse & Seafood Emporium restaurant back room. The measurements throughout various points along the exit access ranged from 10 inches to 23 inches.  a. At the electrical panels area. The exit access width was obstructed with restaurant materials, alcoholic beverages boxes, paint containers, vacuum cleaner, and a water pressure washer. The measurements ranged from 17 inches to 23 inches.    b. At the pool pump room/storage area. The exit access width was obstructed with restaurant materials, extension cords, and miscellaneous The measurements ranged from 10 inches to 21 inches.   NOTE:   Certification of abatement is not required for this citation item since it was submitted prior to citation issuance.
Recent events (1)
  • — Z (S) $4774

1910.303 G01

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 15, 2019
Penalty
Initial $3,580 · Current $3,580
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a. On or about March 7, 2019, at the electrical panels area, at Nates Boathouse & Seafood Emporium restaurant back room. Electrical service panels in the area were not readily accessible. The electrical panels were blocked with restaurant materials, alcoholic beverages boxes, vacuum cleaner, and a water pressure washer.   NOTE:  Certification of abatement is not required for this citation item since it was submitted prior to citation issuance.
Recent events (1)
  • — Z (S) $3580

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343832549.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.