SAVANNAH, GA —
OSHA Inspection: BATISTA CRANE AND RIGGING, LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of BATISTA CRANE AND RIGGING, LLC in 212 WHITESTONE DR, SAVANNAH, GA 31410 (NAICS 238990). OSHA activity number 343835021.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BATISTA CRANE AND RIGGING, LLC
- Site address
- 212 WHITESTONE DR
- City
- SAVANNAH
- State
- GA
- ZIP
- 31410
- Mailing
- 105 BROOKFIELD PL, GUYTON, GA 31312
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.1416 E03
- Issued
- Jun 24, 2019
- Abate by
- Jul 19, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1416(e)(3): Equipment with a telescopic boom, did not have a boom length indicator: A) Job site, on or about March 7, 2019, the length of the extendable boom on a USTC crane serial # 40000374b was not marked.
Recent events (1)
- — Z (O) $0
1926.1416 E04
- Issued
- Jun 24, 2019
- Abate by
- Jul 19, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1416(e)(4)(i): Equipment (other than derricks and articulating cranes) manufactured after March 29, 2003 with a rated capacity over 6,000 pounds did not have at least one of the following: load weighing device, load moment (or rated capacity) indicator, or load moment (or rated capacity) limiter: A) Job site, on or about March 7, 2019, a USTC crane, serial # 40000374b, used to lift roof rafters did not have a load weighing or similar device to determine the weight of the load being lifted by the crane.
Recent events (1)
- — Z (O) $0
1926.1422
- Issued
- Jun 24, 2019
- Abate by
- Jul 19, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1422: 29 CFR 1926.1422: Hand signal charts were not posted on the equipment or conspicuously posted in the vicinity of the hoisting operations: A) Job site, on or about March 7, 2019, a hand signal chart was not posted inside or by the cab of a USTC Crane, serial # 40000374b.
Recent events (1)
- — Z (O) $0
More inspections at Batista Crane and Rigging, LLC
View Batista Crane and Rigging, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238990)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343835021.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.