NEENAH, WI —
OSHA Inspection: VALLEY POPCORN
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of VALLEY POPCORN in 6172 DIXIE ROAD, NEENAH, WI 54956 (NAICS 311999). OSHA activity number 343850061.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VALLEY POPCORN
- Site address
- 6172 DIXIE ROAD
- City
- NEENAH
- State
- WI
- ZIP
- 54956
- Mailing
- 6172 DIXIE ROAD, NEENAH, WI 54956
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311999
- Employees
- 22
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.28 B03 IV
- Issued
- Aug 9, 2019
- Penalty
- Initial $3,789 · Current $1,895 Reduced
General-duty citation text
29 CFR 1910.28(b)(3)(iv): (iv) Each employee is protected from falling into a ladderway floor hole or ladderway platform hole by a guardrail system and toeboards erected on all exposed sides, except at the entrance to the hole, where a self-closing gate or an offset must be used. On or about March 14, 2019, the platform for the 900 mix tank did not have a self-closing gate or offset to protect employees the from fall hazards while working from the platform.
Recent events (2)
- — I (S) $1894.5
- — Z (S) $3789
1910.29 B01
- Issued
- Aug 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.29(b)(1): (1) The top edge height of top rails, or equivalent guardrail system members, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface. The top edge height may exceed 45 inches (114 cm), provided the guardrail system meets all other criteria of paragraph (b) of this section (see Figure D-11). On or about March 14, 2019, the chain being used as a top rail of a guardrail system did not maintain a top edge height of 42 inches, plus or minus 3 inches, and exposed employees to potential falls while working in Pop Room 1.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.29 B02
- Issued
- Aug 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.29(b)(2): (2) Midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent intermediate members are installed between the walking-working surface and the top edge of the guardrail system as follows when there is not a wall or parapet that is at least 21 inches (53 cm) high: On or about March 14, 2019, employees of Valley Popcorn were exposed to fall hazards when the mid-rail chain serving as fall protection between the wall and stairwell in Pop Room 1 did not maintain a top edge height of 21 inches.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C01
- Issued
- Aug 9, 2019
- Abate by
- Sep 9, 2019
- Penalty
- Initial $3,031 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. On or about March 14, 2019, Valley Popcorn had not developed and implemented a program to control potentially hazardous energy sources for employees conducting maintenance and service activities on machinery within their facility.
Recent events (2)
- — I (S) $0
- — Z (S) $3031
1910.178 L04 III
- Issued
- Aug 9, 2019
- Abate by
- Sep 9, 2019
- Penalty
- Initial $3,031 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years. On or about March 14, 2019, Valley Popcorn had not conducted an evaluation of each powered industrial truck operator's performance every three years as required by the standard.
Recent events (2)
- — I (O) $0
- — Z (S) $3031
1910.305 B01 II
- Issued
- Aug 9, 2019
- Abate by
- Sep 9, 2019
- Penalty
- Initial $3,031 · Current $1,516 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. On or about March 14, 2019, knockout plugs were missing from: a) an electrical box mounted to the ceiling in Pop Room 1 that had a fire alarm wired to the box and had wires visible in the opening. b) an electrical box mounted to the ceiling in Pop room 1 that had the nearby light fixture plugged into it.
Recent events (2)
- — I (S) $1515.5
- — Z (S) $3031
1910.305 B02 I
- Issued
- Aug 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. On or about March 14, 2019, an electrical switch, located above the sink in Pop Room 1, was missing a faceplate exposing the internal wiring of the electrical outlet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Aug 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure. On or about March 14, 2019, Valley Popcorn was utilizing an extension cord to power a Navien tankless water heater instead of fixed wiring.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Aug 9, 2019
- Penalty
- Initial $2,273 · Current $1,137 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met. On or about March 14, 2019, Valley Popcorn had not developed and maintained a written Hazard Communication Program.
Recent events (2)
- — I (S) $1136.5
- — Z (S) $2273
1910.1200 F06
- Issued
- Aug 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6): Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked. On or about March 14, 2019, several bottles of Warsaw Chemical Orange 88 Degreaser, diluted with water, were observed throughout the plant and did not have label indicating the name of the substance and the physical and health hazards of the substance.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Aug 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets. On or about March 14, 2019, Valley Popcorn had not provided training to their employees on the hazardous chemicals in their respective work areas.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Valley Popcorn
View Valley Popcorn's full OSHA safety record →
More inspections in this industry (NAICS 311999)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343850061.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.