Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: CIRCUITS WEST, INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CIRCUITS WEST, INCORPORATED in 410 S. SUNSET SUITE D, LONGMONT, CO 80501 (NAICS 334412). OSHA activity number 343882908.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Circuits West, Incorporated for free Get an email when a new federal OSHA severe-injury report for Circuits West, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
410 S. SUNSET SUITE D
City
LONGMONT
State
CO
ZIP
80501
Mailing
410 S. SUNSET SUITE D, LONGMONT, CO 80501
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334412
Employees
36
Ownership type
A

9 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 1 10 instances 3 exposed
Issued
Jun 7, 2019
Abate by
Jul 25, 2019
Penalty
Initial $3,381 · Current $2,000 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items of this section:    (a)   Circuits West, Incorporated, at 410 S. Sunset Suite D, Longmont, CO: On and preceding March 26, 2019, the employer did not establish clear and specific procedures to outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy in that the instructions concerning energy control were general. Employees from maintenance and production were routinely exposed to the hazards of inadequate lockout procedures during maintenance and cleaning activities for, but not limited to, equipment such as the HASL, scrubbers, driller/routers, presses, and ovens. This condition exposed employees to hazards associated with equipment or machines that contain multiple sources of energy capable of injuring an employee while performing servicing, cleaning, and maintenance activities.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $3381

1910.147 C06 I

Serious Gravity 5 10 instances 3 exposed
Issued
Jun 7, 2019
Abate by
Jul 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   (a)   Circuits West, Incorporated, at 410 S. Sunset Suite D, Longmont, CO: On and preceding March 26, 2019, the employer did not conduct a periodic inspection at least annually of the Lockout/Tagout (LOTO) procedures used by maintenance personnel. This condition exposed employees to crushing and amputation hazards associated with equipment such as, but not limited to the HASL, scrubbers, driller/routers, presses, and ovens.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 7, 2019
Abate by
Jul 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i):  The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:    (a)   Circuits West, Incorporated, at 410 S. Sunset Suite D, Longmont, CO: On and preceding March 26, 2019, the employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees in that the instructions concerning energy control were general. This condition exposed the employees to the hazards of improper lockout procedures for, but not limited to the HASL, scrubbers, driller/routers, presses, and ovens.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.151 C

Serious Gravity 5 2 instances 6 exposed
Issued
Jun 7, 2019
Abate by
Jul 25, 2019
Penalty
Initial $5,636 · Current $3,400 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    (a) Circuits West, Incorporated, at 410 S. Sunset Suite D Longmont, CO: On and preceding March, 27, 2019, the employer did not ensure where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use. Employees from the plating room were routinely exposed to corrosive chemical hazards during production or maintenance activities. Employees used chemicals such as but not limited to sulfuric acid 10%~1%, ss200 tin strip, promoter 3308. The eye wash and shower on the south side was blocked and was not inspected for suitable working condition in that when demonstrated, rust came out of shower head. This condition exposed the employees to corrosive chemical hazards.    (b) Circuits West, Incorporated, at 410 S. Sunset Suite D Longmont, CO: On and preceding March, 27, 2019, the employer did not ensure where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes were not provided within the work area for immediate emergency use. Employees from the plating room were routinely exposed to corrosive chemical hazards during production or maintenance activities. Employees used chemicals such as but not limited to sulfuric acid 10%~1%, ss200 tin strip, promoter 3308. The eye wash on the north side was not inspected for suitable working condition and caps were missing. This condition exposed the employees to corrosive chemical hazards.
Recent events (2)
  • · I (S) $3400
  • · Z (S) $5636

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 7, 2019
Abate by
Jul 25, 2019
Penalty
Initial $5,636 · Current $3,400 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) such as those created by rotating parts and in-going nip points:    (a) Circuits West, Incorporated, at 410 S. Sunset Suite D Longmont, CO: On and preceding March, 26, 2019, the employer did not ensure that machine guarding was provided to protect operator(s) and other employees from hazard(s) such as those created by ingoing nip points and rotating parts. Operators were routinely exposed to safety hazards during production on the A5 Neo Flying Probe machine because the protective hood was not closed. The machine was set to operate with the keyed service switch in a position which defeated the interlock to the hood guard. This condition exposed the employees to caught-in-between, crushing and amputation hazards.     (b) Circuits West, Incorporated, at 410 S. Sunset Suite D Longmont, CO: On and preceding March, 26, 2019, the employer did not ensure that machine guarding was provided to protect operator(s) and other employees from hazard(s) such as those created by ingoing nip points and rotating parts. Operators were routinely exposed to safety hazards during production on the Microcraft ELX 6146 machine because the front door guards were open. The machine was operating with the front door guards open because the safety interlock was defeated/bypassed. This condition exposed the employees to caught-in-between, crushing and amputation hazards.      (c)   Circuits West, Incorporated, at 410 S. Sunset Suite D, Longmont, CO: On and preceding March, 26, 2019, the employer did not ensure that machine guarding was provided to protect operator(s) and other employees from hazard(s) such as those created by ingoing nip points and rotating parts. Operators were routinely exposed to safety hazards during production on the Apollon-D1-F10 machine because the side cover had been removed for servicing and left in that condition for approximately one month. This condition allowed operators access to moving mechanical parts during production tasks and exposed them to caught-in-between, crushing and amputation hazards.
Recent events (2)
  • · I (S) $3400
  • · Z (S) $5636

1910.215 B09

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 7, 2019
Abate by
Jul 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:   (a) Circuits West, Incorporated, at 410 S. Sunset Suite D Longmont, CO: On and preceding March, 27, 2019, in the maintenance room there was no tongue guard installed on the pedestal grinder. This condition exposed employees to struck-by hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B02 I

Serious Gravity 1 1 instance 4 exposed
Issued
Jun 7, 2019
Abate by
Jul 25, 2019
Penalty
Initial $3,381 · Current $2,000 Reduced
29 CFR 1910.305(b)(2)(i):  Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    (a) Circuits West, Incorporated, at 410 S. Sunset Suite D Longmont, CO: On and preceding March, 26, 2019, the employer did not ensure that the Ion electrical junction box located in the plating room was covered, thus potentially exposing employees to energized electrical parts. This condition exposed the employees to electrical hazards.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $3381

1910.305 G01 IV A

Serious Gravity 1 1 instance 4 exposed
Issued
Jun 7, 2019
Abate by
Jul 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):  Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   (a) Circuits West, Incorporated, at 410 S. Sunset Suite D Longmont, CO: On and preceding March, 26, 2019, the employer did not ensure that flexible cords were not used as a substitute for the fixed wiring of a structure exposing employees to electrical hazards. The cord located in the plating room behind the shower and eye wash station was providing power to a device used in production and/or maintenance. This condition exposed employees to electrical hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.132 D02

Deleted Other-than-serious 1 instance 25 exposed
Issued
Jun 7, 2019
Abate by
Jul 3, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment had been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2):  (a) Circuits West, Incorporated, at 410 S. Sunset Suite D Longmont, CO: On and preceding March, 26, 2019, the employer did not ensure through written verification that a workplace personal protective equipment (PPE) hazard assessment had been performed.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Circuits West, Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343882908.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.