POST FALLS, ID —
OSHA Inspection: A & A CONSTRUCTION & DEVELOPMENT, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of A & A CONSTRUCTION & DEVELOPMENT, INC in 1120 EAST 4TH, POST FALLS, ID 83854 (NAICS 236116). OSHA activity number 343898979.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A & A CONSTRUCTION & DEVELOPMENT, INC
- Site address
- 1120 EAST 4TH
- City
- POST FALLS
- State
- ID
- ZIP
- 83854
- Mailing
- 108 NORTH WASHINGTON SUITE 603, SPOKANE, WA 99201
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.20 B02
- Issued
- May 23, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $1,932 · Current $0 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a) Jobsite: On April 2, 2019 and times prior thereto the controlling employer, A & A Construction & Development, did not ensure their sub-contractors protected their employees from the improper use of electrical equipment. The weekly site inspections conducted by the controlling employer did not identify and correct a portable power distribution unit, spider box, that was hanging by a power cord from a temporary power pole. b) Jobsite: On April 2, 2019 and times prior thereto the controlling employer, A & A Construction & Development, did not ensure their sub-contractors protected their employees from potential shock and fire hazards where cardboard and other material was used as a cover for energized power panels. The weekly site inspections conducted by the controlling employer did not identify and correct the potential fire hazard. c) Jobsite: On April 2, 2019 and times prior thereto the controlling employer, A & A Construction & Development, did not ensure their sub-contractors protected their employees from protruding nails in boards laying on the ground. The weekly site inspections conducted by the controlling employer did not identify and correct the housekeeping hazard. d) Jobsite: On April 2, 2019 and times prior thereto the controlling employer, A & A Construction & Development, did not ensure their sub-contractors protected their employees from unguarded fans on the Cadet Com-Pak wall heaters used in several units. The weekly site inspections conducted by the controlling employer did not identify and correct the missing front covers on the heaters. Note) Certification of corrective actions are required for these items.
Recent events (2)
- — I (S) $0
- — Z (S) $1932
1926.25 A
- Issued
- May 23, 2019
- Penalty
- Initial $0 · Current $1,200
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: a) Jobsite: On April 2, 2019 and at times prior thereto the controlling employer, A & A Construction & Development, Inc., did not ensure that their employees were protected and that the sub-contractor(s) protected its employees from puncture wound hazards where protruding nails were left in scrap wood. Note) Certification of corrective action is required for this item.
Recent events (2)
- — I (O) $1200
- — Z (S) $0
1926.403 B01
- Issued
- May 23, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $2,415 · Current $0 Reduced
General-duty citation text
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: a) Jobsite: On April 2, 2019 and times prior thereto the controlling employer, A & A Construction & Development, did not ensure their sub-contractors protected their employees from potential shock and fire hazards in where cardboard and other material was used as a cover for 120/208 volt power panels. b) Jobsite: On April 2, 2019 and times prior thereto the controlling employer, A & A Construction & Development, did not ensure their sub-contractors protected their employees from the improper use of electrical equipment. A portable power distribution unit, "spider box", hanging by a power cord from a temporary power pole, was being used by a sub-contractor. Note) Certification of corrective actions are required for these items.
Recent events (2)
- — I (O) $0
- — Z (S) $2415
1926.403 B02
- Issued
- May 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Jobsite: On April 2, 2019 and times prior thereto the controlling employer, A & A Construction & Development, did not ensure their sub-contractors protected their employees from the improper use of electrical equipment. A portable power distribution unit, "spider box", hanging by a power cord from a temporary power pole, and was being used by a sub-contractor. Note) Certification of corrective action is required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.405 G02 IV
- Issued
- May 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Jobsite: On April 2, 2019 and times prior thereto the controlling employer, A & A Construction & Development, did not ensure their sub-contractors protected their employees from the improper use of electrical equipment. A portable power distribution unit, "spider box", was hanging by a power cord from a temporary power pole. Strain relief was not in place on both ends of the power cord. Note) Corrected during inspection.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.405 D
- Issued
- May 23, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $0 · Current $1,500
General-duty citation text
29 CFR 1926.405(d): Panel boards mounted in cabinets, cutout boxes or enclosures designed for the purpose were not dead front: a) Jobsite: On April 2, 2019 and times prior thereto the controlling employer, A & A Construction & Development, did not ensure their sub-contractors protected their employees from potential shock and fire hazards where cardboard and other material was used as a cover on 120/208 volt power panels. Note) Certification of corrective action is required for this item.
Recent events (2)
- — I (S) $1500
- — Z (S) $0
More inspections at A & a Construction & Development, INC
View A & a Construction & Development, INC's full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343898979.