OSHA Inspection: COCA COLA CONSOLIDATED

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COCA COLA CONSOLIDATED in 5100 DUCK CREEK ROAD, CINCINNATI, OH 45227 (NAICS 312111). OSHA activity number 343913174.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coca Cola Consolidated — free Get an email when a new federal OSHA severe-injury report for Coca Cola Consolidated is published. One employer, no account, unsubscribe in one click.
Site address
5100 DUCK CREEK ROAD
City
CINCINNATI
State
OH
ZIP
45227
Mailing
5100 DUCK CREEK ROAD, CINCINNATI, OH 45227
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
312111
Employees
450
Ownership type
A

3 citations on file for this inspection.

1910.178 M05 II

Deleted Serious Gravity 10 2 instances 2 exposed
Issued
Jul 18, 2019
Abate by
Aug 13, 2019
Penalty
Initial $13,260 · Current $0 Reduced
29 CFR 1910.178(m)(5)(ii): A powered industrial truck is unattended when the operator is 25 ft. or more away from the vehicle which remains in his view, or whenever the operator leaves the vehicle and it is not in his view.  a)On 4/8/2019 a powered industrial truck was still running when it (Toyota Model # 7FBCU30) was left unattended with no operator within 25 ft. of the running PIV.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13260

1910.178 P01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jul 18, 2019
Abate by
Aug 13, 2019
Penalty
Initial $13,260 · Current $0 Reduced
29 CFR 1910.178(p)(1): If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.  a) On 6/5/2019 the employer allowed employees to operate a Caterpillar Forklift (EO3DX) that would continue to run without a key inserted in the ignition.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13260

1910.178 Q07

Other-than-serious 1 instance 1 exposed
Issued
Jul 18, 2019
Abate by
Aug 13, 2019
Penalty
Initial $13,260 · Current $8,000 Reduced
29 CFR 1910.178(q)(7): Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected.    a) The employer did not ensure that PIV operators were completing the daily examination checklist in order to show any condition that could adversely effect the condition of the PIVs such as PIVs engines ability to run without a key, PIVs being keyed to a single key.