MAMARONECK, NY —
OSHA Inspection: ADVANCED WALL SYSTEMS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ADVANCED WALL SYSTEMS, INC. in 805 MAMARONECK AVE., MAMARONECK, NY 10543 (NAICS 238320). OSHA activity number 343918322.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED WALL SYSTEMS, INC.
- Site address
- 805 MAMARONECK AVE.
- City
- MAMARONECK
- State
- NY
- ZIP
- 10543
- Mailing
- 2 INLAND CT., CARMEL, NY 10512
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 6
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.416 E01
- Issued
- Sep 30, 2019
- Penalty
- Initial $2,273 · Current $2,273
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: location: 805 Mamaroneck Ave., Mamaroneck, NY 10543, sidewalk area on or about: 4/9/19 a) An employee was using extension cords to power a Chicago Electric spade handle drill, while engaged in exterior insulation and finish system (EIFS) work. One of the extension cords was damaged, with exposed metal showing. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
- — Z (S) $2273
1926.451 E01
- Issued
- Sep 30, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: location: 805 Mamaroneck Ave., Mamaroneck, NY 10543, exterior of building on or about: 4/9/19 a) Employees were working on a scaffold that was 22' high. The employees used the crossbraces and walk through frames as a means of access. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
- — Z (S) $2842
1926.454 A
- Issued
- Sep 30, 2019
- Abate by
- Nov 1, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.454(a): The employer shall have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: location: 805 Mamaroneck Ave., Mamaroneck, NY 10543, entire site on or about: 4/9/19 a) Employees were working from tubular welded frame scaffolding. Two of the employees were not provided with scaffold safety training. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $3978
1926.701 B
- Issued
- Sep 30, 2019
- Penalty
- Initial $1,705 · Current $1,705
General-duty citation text
29 CFR 1926.701(b): Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, was not guarded to eliminate the hazard of impalement: Location: 805 Mamaroneck Ave., Mamaroneck, NY 10543, sidewalk area on or about: 4/9/19 a) Employees were walking beside 10 unguarded rebar. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
- — Z (S) $1705
1926.1053 B01
- Issued
- Sep 30, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: location: 805 Mamaroneck Ave., Mamaroneck, NY 10543, exterior of building on or about: 4/9/19 a) Employees gained access to and from the tubular welded frame scaffolding using an extension ladder that extended only 1 foot above the upper landing surface. location: 805 Mamaroneck Ave., Mamaroneck, NY 10543, exterior of building on or about: 4/9/19 b) Employees gained access to and from the tubular welded frame scaffolding using a Little Giant metal ladder that extended only a few inches above the upper landing surface. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
- — Z (S) $2842
1926.451 G01
- Issued
- Sep 30, 2019
- Penalty
- Initial $26,520 · Current $26,520
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level: location: 805 Mamaroneck Ave., Mamaroneck, NY 10543, exterior of building on or about: 4/9/19 a) Employees were working from tubular welded frame scaffolding, while applying EFIS to the exterior of the building. The employees, who were not provided with fall protection, were exposed to a fall of 22 feet. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
- — Z (W) $26520
1926.403 B02
- Issued
- Sep 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Installation and use. Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: location: 805 Mamaroneck Ave., Mamaroneck, NY 10543, exterior of building on or about: 4/9/19 a) A quad receptacle was not installed in accordance with its listing. It was attached to the end of an extension cord and it was not mounted. The receptacle was used by an employee to power a Chicago Electric spade handle drill, while engaged in exterior insulation and finish system (EIFS) work. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
- — Z (O) $0
1926.404 F06
- Issued
- Sep 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent and continuous: location: 805 Mamaroneck Ave., Mamaroneck, NY 10543, exterior of building on or about: 4/9/19 a) An employee was using extension cords to power a Chicago Electric spade handle drill, while engaged in exterior insulation and finish system (EIFS) work. The grounding pins for two of the extension cords were missing. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
- — Z (O) $0
1926.405 G02 IV
- Issued
- Sep 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: location: 805 Mamaroneck Ave., Mamaroneck, NY 10543, exterior of building on or about: 4/9/19 a) An employee was using extension cords to power a Chicago Electric spade handle drill, while engaged in exterior insulation and finish system (EIFS) work. The strain relief on the extension cord was broken, and the outer plastic sheath was pulled away from the plug. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
- — Z (O) $0
More inspections at Advanced Wall Systems, INC.
View Advanced Wall Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238320)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343918322.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.