Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PEREZ COMMERCIAL CONSTRUCTION, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of PEREZ COMMERCIAL CONSTRUCTION, LLC in 4554 LARIMER STREET, DUBLIN, OH 43017 (NAICS 238130). OSHA activity number 343919221.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Perez Commercial Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Perez Commercial Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4554 LARIMER STREET
City
DUBLIN
State
OH
ZIP
43017
Mailing
957 BEECHWOOD ROAD, COLUMBUS, OH 43227
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
18
Ownership type
A

2 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 1 instance 15 exposed
Issued
Jun 6, 2019
Penalty
Initial $4,168 · Current $4,168
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.   a. Located at 4554 Larimer Street in Dublin, Ohio: On or about April 6, 2019, employees were performing framing work from the buildings fourth floor. Openings between the exterior stud walls and the guardrail end posts at the Northeast corner of the building exposed employees and other contractor employees to a fall hazard to the ground below.
Recent events (1)
  • — Z (S) $4168

1926.502 B03

Serious Gravity 10 1 instance 14 exposed
Issued
Jun 6, 2019
Penalty
Initial $5,834 · Current $5,834
29 CFR 1926.502(b)(3): Guardrail systems shall be capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge.   a. Located at 4554 Larimer Street in Dublin, Ohio: On or about April 6, 2019, employees were performing framing work from the third floor. The employer did not ensure that the temporary guardrail system erected at the Northeast corner opening was properly supported, thereby exposing employees and other contractor employees to a fall hazard to the ground below.
Recent events (1)
  • — Z (S) $5834

View Perez Commercial Construction, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343919221.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.