FORT LAUDERDALE, FL —
OSHA Inspection: GENERATION 2000 ENTERPRISES INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of GENERATION 2000 ENTERPRISES INC. in 2700 WEST BROWARD BLVD., FORT LAUDERDALE, FL 33312 (NAICS 238110). OSHA activity number 343926275.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GENERATION 2000 ENTERPRISES INC.
- Site address
- 2700 WEST BROWARD BLVD.
- City
- FORT LAUDERDALE
- State
- FL
- ZIP
- 33312
- Mailing
- 530 NW 20 STREET, HOMESTEAD, FL 33030
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 4
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.25 A
- Issued
- Jul 1, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $3,126 · Current $3,126
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form or scrap lumber with protruding nails was not kept clear from work areas: On or about 04/10/2019, at 2700 West Broward Blvd., Fort Lauderdale, Florida, employees were exposed to trip and fall hazards from debris around the base of the scaffold.
Recent events (3)
- — J (S) $3126
- — C (S) $3126
- — Z (S) $3126
1926.451 B01
- Issued
- Jul 1, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $3,751 · Current $3,751
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports: On or about 04/10/2019, at 2700 West Broward Blvd., Fort Lauderdale, Florida, employees were working from a fabricated frame scaffold that was not fully planked exposing them to a fall hazard.
Recent events (3)
- — J (S) $3751
- — C (S) $3751
- — Z (S) $3751
1926.451 B10
- Issued
- Jul 1, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $3,751 · Current $3,751
General-duty citation text
29 CFR 1926.451(b)(10): Scaffold components manufactured by different manufacturers were modified in order to intermix them and a competent person did not determine that the resulting scaffold was structurally sound: On or about 04/10/2019, at 2700 West Broward Blvd., Fort Lauderdale, Florida, employees were working from scaffolding that was assembled using different components exposing employees to fall hazards.
Recent events (3)
- — J (S) $3751
- — C (S) $3751
- — Z (S) $3751
1926.451 C02
- Issued
- Jul 1, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $2,500 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about 04/10/2019, at 2700 West Broward Blvd., Fort Lauderdale, Florida, employees were working from a scaffold that did not have base plates or mudsills exposing them to a fall hazard.
Recent events (3)
- — J (S) $0
- — C (S) $2500
- — Z (S) $2500
1926.451 E01
- Issued
- Jul 1, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $3,751 · Current $3,751
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about 04/10/2019, at 2700 West Broward Blvd., Fort Lauderdale, Florida, employees were climbing on the cross bracing of a fabricated frame scaffold exposing them to a fall hazard.
Recent events (3)
- — J (S) $3751
- — C (S) $3751
- — Z (S) $3751
1926.451 E09 IV
- Issued
- Jul 1, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $3,751 · Current $3,751
General-duty citation text
29 CFR 1926.451(e)(9)(iv): Cross braces on tubular welded frame scaffolds were used as a means of access or egress. On or about 04/10/2019, at 2700 West Broward Blvd., Fort Lauderdale, Florida, employees climbing cross braces on a scaffold were exposed to fall hazards.
Recent events (3)
- — J (S) $3751
- — C (S) $3751
- — Z (S) $3751
1926.451 F03
- Issued
- Jul 1, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $4,376 · Current $4,376
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) On or about 04/10/2019, at 2700 West Broward Blvd., Fort Lauderdale, Florida, the employer failed to ensure that a scaffold with defects was inspected prior to allowing employees to work from the scaffold thus exposing them to a fall hazard.
Recent events (3)
- — J (S) $4376
- — C (S) $4376
- — Z (S) $4376
1926.1051 A
- Issued
- Jul 1, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $1,875 · Current $1,875
General-duty citation text
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: On or about 04/10/2019, at 2700 West Broward Blvd., Fort Lauderdale, Florida, employees climbing from a roof deck to a lower deck, with an elevation greater than nineteen inches, were not provided with a ladder exposing them to a fall hazard.
Recent events (3)
- — J (S) $1875
- — C (S) $1875
- — Z (S) $1875
1926.1053 B04
- Issued
- Jul 1, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $2,500 · Current $2,500
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: On or about 04/10/2019, at 2700 West Broward Blvd., Fort Lauderdale, Florida, employees were using one section of an extension ladder and a stepladder to access a roof exposing them to a fall hazard.
Recent events (3)
- — J (S) $2500
- — C (S) $2500
- — Z (S) $2500
More inspections at Generation 2000 Enterprises INC.
View Generation 2000 Enterprises INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238110)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343926275.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.