SAN ANTONIO, TX —
OSHA Inspection: COILPLUS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COILPLUS INC. in 6610 RAILWAY, SAN ANTONIO, TX 78244 (NAICS 331221). OSHA activity number 343928180.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COILPLUS INC.
- Site address
- 6610 RAILWAY
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78244
- Mailing
- 6610 RAILWAY, SAN ANTONIO, TX 78244
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331221
- Employees
- 400
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 A01
- Issued
- Oct 10, 2019
- Penalty
- Initial $5,683 · Current $3,410 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition: Production Area: On or about April 12, 2019, machine operators were exposed to slip and trip hazards while operating the Stamco Slitter from an oily residue on the floor.
Recent events (2)
- — I (S) $3409.8
- — Z (S) $5683
1910.29 B02 I
- Issued
- Oct 10, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $7,577 · Current $4,546 Reduced
General-duty citation text
29 CFR 1910.29(b)(2)(i): Midrails were not installed at a height midway between the top edge of the guardrail system and the walking-working surface: On or about April 12, 2019, and at times prior thereto, employees were exposed to a fall hazard while working near the loop pit that did not have a midrail installed at 21 inches high.
Recent events (2)
- — I (S) $4546.2
- — Z (S) $7577
1910.184 I09 III
- Issued
- Oct 10, 2019
- Penalty
- Initial $5,683 · Current $3,410 Reduced
General-duty citation text
29 CFR 1910.184(i)(9)(iii): Synthetic web sling(s) with snags, punctures, tears, or cuts were not immediately removed from service: In the Receiving Area: On or about April 12, 2019, and at times prior thereto, employees were exposed to a struck-by hazard, while utilizing a PL 10 x 24 Polyester Round Sling to lift coils which had evidence of tears and fraying.
Recent events (2)
- — I (S) $3409.8
- — Z (S) $5683
1910.303 B02
- Issued
- Oct 10, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $5,683 · Current $3,410 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: In the Production Line Area: On or about April 12, 2019, and at times prior thereto, employees were exposed to an electrical hazard while using a power strip that was plugged into another power strip and to an extension cord underneath a work desk.
Recent events (2)
- — I (S) $3409.8
- — Z (S) $5683
1910.37 B05
- Issued
- Oct 10, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): In the Receiving Area: On or about April 12, 2019, and at times prior thereto, employees were exposed to a fire hazard, door #8 was not marked by a sign to indicate it was not an exit.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Coilplus INC.
View Coilplus INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331221)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343928180.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.