OSHA Inspection: PRICE-BRAKE CONSTRUCTION, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRICE-BRAKE CONSTRUCTION, LLC in 2602 29TH. ST., NW, WASHINGTON, DC 20015 (NAICS 236115). OSHA activity number 343929709.

Watch Price-Brake Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Price-Brake Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2602 29TH. ST., NW
City
WASHINGTON
State
DC
ZIP
20015
Mailing
1028 33RD. ST., NW, SUITE 320, WASHINGTON, DC 20007
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
1
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 9, 2019
Abate by
Oct 29, 2019
Penalty
Initial $2,899 · Current $1,700 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):      (a) Garage Roof - On or about 04/09/2019, construction workers were exposed to a 10 foot fall from the unprotected edge of an open-sided floor for the wire rope guradrials that had originally surrounded the area were removed.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $1700
  • — Z (S) $2899

1926.701 B

Serious Gravity 5 1 instance 4 exposed
Issued
Oct 9, 2019
Abate by
Oct 25, 2019
Penalty
Initial $2,416 · Current $1,600 Reduced
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement:     a)  Driveway - On or about April 10, 2019, two 1/2 inch vertical rebar were left unprotected by the main entrance to a building under construction.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2416

1926.1052 C01 I

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 9, 2019
Abate by
Oct 25, 2019
Penalty
Initial $1,932 · Current $1,000 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:      a)        Ground Level to First Floor - On or about April 09, 2019, construction workers were exposed to up to a 12 foot fall from a set of interior stairs having more than four risers that were not provided with a handrail.       b)      First to Third Floors - On or about April 10, 2019, construction workers were exposed to up to a 12 foot fall from a set of interior stairs having more than four risers that were not provided with a handrail.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1932

1926.1052 C01 II

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 9, 2019
Abate by
Oct 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:   a)        Ground Level to First Floor - On or about April 09, 2019, construction workers were exposed to up to a 12 foot fall from a set of interior stairs having more than four risers that were not provided with a stairrail on its one open side.     b)      First to Third Floors - On or about April 09, 2019, construction workers were exposed to up to a 12 foot fall from a set of interior stairs having more than four risers that were not provided with a stairrail on its one open side.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Price-Brake Construction, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343929709.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.