HALEYVILLE, AL ·
OSHA Inspection: MASONITE CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MASONITE CORPORATION in 210 HALEYVILLE INDUSTRIAL ROAD, HALEYVILLE, AL 35565 (NAICS 321911). OSHA activity number 343932109.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MASONITE CORPORATION
- Site address
- 210 HALEYVILLE INDUSTRIAL ROAD
- City
- HALEYVILLE
- State
- AL
- ZIP
- 35565
- Mailing
- P.O. BOX DRAWER F, HALEYVILLE, AL 35565
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321911
- Employees
- 294
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jun 25, 2019
- Abate by
- Jul 22, 2019
- Penalty
- Initial $11,366 · Current $6,820 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about 03/26/2019 - Layup Department, procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities such as cleaning the glue machine.
Recent events (2)
- · I (S) $6819.6
- · Z (S) $11366
1910.147 C07 I
- Issued
- Jun 25, 2019
- Abate by
- Jul 22, 2019
- Penalty
- Initial $11,366 · Current $6,820 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) On or about 03/26/2019 - Layup Department, employees cleaning the glue machine had not been trained in the procedures to be followed for the control of hazardous energy.
Recent events (2)
- · I (S) $6819.6
- · Z (S) $11366
More inspections at Masonite Corporation
View Masonite Corporation's full OSHA safety record →
More inspections in this industry (NAICS 321911)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343932109.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.