TAMPA, FL —
OSHA Inspection: T.D. THOMSON CONSTRUCTION CO. INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of T.D. THOMSON CONSTRUCTION CO. INC. in 5224-5200 WILLIAMS RD., TAMPA, FL 33610 (NAICS 237110). OSHA activity number 343933859.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- T.D. THOMSON CONSTRUCTION CO. INC.
- Site address
- 5224-5200 WILLIAMS RD.
- City
- TAMPA
- State
- FL
- ZIP
- 33610
- Mailing
- 1055 VINELAND RD, WINTER GARDEN, FL 34787
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 12
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.100 A
- Issued
- Jul 18, 2019
- Abate by
- Aug 13, 2019
- Penalty
- Initial $3,789 · Current $2,463 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a. On or about April 16, 2019, at the east side of 5200 Williams Rd., Tampa, FL, employees working inside and around an open trench with overhead hazards present were not wearing hardhats.
Recent events (2)
- — I (S) $2462.85
- — Z (S) $3789
1926.651 C02
- Issued
- Jul 18, 2019
- Abate by
- Aug 13, 2019
- Penalty
- Initial $3,789 · Current $2,463 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a. On or about April 16, 2019, at the east side of 5200 Williams Rd, Tampa, FL, the open trench excavation, measuring 27 feet in length and between 5 feet, 4 inches to 9 feet deep, did not have a safe mean of egress, exposing employees to struck-by and cave-in hazards.
Recent events (2)
- — I (S) $2462.85
- — Z (S) $3789
1926.652 A01
- Issued
- Jul 18, 2019
- Abate by
- Aug 13, 2019
- Penalty
- Initial $3,789 · Current $2,463 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: a. On or about April 16, 2019, at the east side of 5200 Williams Rd, Tampa, FL, two employees working on a water pipeline inside an unprotected trench 9 feet deep were exposed to struck-by and cave-in hazards.
Recent events (2)
- — I (S) $2462.85
- — Z (S) $3789
More inspections at T.D. Thomson Construction CO. INC.
View T.D. Thomson Construction CO. INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343933859.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.