CORPUS CHRISTI, TX —
OSHA Inspection: UNITED ERECTORS 2 LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UNITED ERECTORS 2 LLC in 3875 S STAPLES ST, CORPUS CHRISTI, TX 78411 (NAICS 238120). OSHA activity number 343937751.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITED ERECTORS 2 LLC
- Site address
- 3875 S STAPLES ST
- City
- CORPUS CHRISTI
- State
- TX
- ZIP
- 78411
- Mailing
- 5504 BANDERA RD STE 402, SAN ANTONIO, TX 78238
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B04 II
- Issued
- Apr 23, 2019
- Penalty
- Initial $4,376 · Current $4,376
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers: Employees worked adjacent to a unguarded elevator shaft/pit.
Recent events (1)
- — Z (S) $4376
1926.701 B
- Issued
- Apr 23, 2019
- Penalty
- Initial $3,126 · Current $3,126
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement: Employees worked adjacent to and above an elevator shaft/pit with unguarded protruding rebar.
Recent events (1)
- — Z (S) $3126
1926.453 B02 V
- Issued
- Apr 23, 2019
- Penalty
- Initial $15,629 · Current $15,629
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:Note: As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated: An employee conducted welding activities from an aerial lift without fall protection. United Erectors 2 LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.453(b)(2)(v), which was contained in OSHA inspection number 1193936, citation number 2, item number 2 and was affirmed as a final order on March 3, 2017, with respect to a workplace located at 7022 S New Braunfels Ave, San Antonio, TX 78238.
Recent events (1)
- — Z (R) $15629
More inspections at United Erectors 2 LLC
View United Erectors 2 LLC's full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343937751.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.