SCHAUMBURG, IL —
OSHA Inspection: ADVANCED ROOFING SYSTEMS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADVANCED ROOFING SYSTEMS, INC. in 1020 GOLF ROAD, SCHAUMBURG, IL 60159 (NAICS 238160). OSHA activity number 343939450.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED ROOFING SYSTEMS, INC.
- Site address
- 1020 GOLF ROAD
- City
- SCHAUMBURG
- State
- IL
- ZIP
- 60159
- Mailing
- 1924 N. ELM STREET, MUNCIE, IN 47303
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Apr 30, 2019
- Abate by
- May 6, 2019
- Penalty
- Initial $5,304 · Current $3,210 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) On or about April 17, 2019, employees were exposed to head injury while working without protective helmets in areas below roofing operations. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $3210
- — Z (S) $5304
1926.501 B01
- Issued
- Apr 30, 2019
- Abate by
- May 6, 2019
- Penalty
- Initial $9,282 · Current $5,570 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On or about April 17, 2019, employees were exposed to the hazard of falling approximately 18 feet while disposing of debris at the roof edge where fall protection had not been provided. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $5570
- — Z (S) $9282
1926.501 B10
- Issued
- Apr 30, 2019
- Abate by
- May 6, 2019
- Penalty
- Initial $9,282 · Current $5,570 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: a) On or about April 17, 2019, employees were not protected from the hazard of falling approximately 18 and 21 feet from the roof edge to the exterior of the building while engaged in roofing activities without the benefit of fall protection or a warning line and safety monitoring system. b) On or about April 17, 2019, employees were not protected from the hazard of falling approximately 8 feet from the roof edge to an interior roof deck of the building while engaged in roofing activities without the benefit of fall protection or a warning line and safety monitoring system. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $5570
- — Z (S) $9282
1926.502 F01
- Issued
- Apr 30, 2019
- Abate by
- May 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area: a) On or about April 17, 2019, warning lines were not erected around all sides of the roof work area. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 F01 I
- Issued
- Apr 30, 2019
- Abate by
- May 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(1)(i): When no mechanical equipment was being used the warning line was not erected at least 6 feet (1.8m) from the roof edge: a) On or about April 17, 2019, warning lines were erected within 6 feet of the north edge of the roof. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 F01 III
- Issued
- Apr 30, 2019
- Abate by
- May 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines: a) On or about April 17, 2019, warning lines were not used to create access paths connecting the work area to the point of access along the roof edge. b) On or about April 17, 2019, warning lines were not used to create access paths connecting the work area to the debris removal area along the roof edge. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Advanced Roofing Systems, INC.
View Advanced Roofing Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343939450.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.