COLLEGEVILLE, PA ·
OSHA Inspection: H&K GROUP, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of H&K GROUP, INC. in 430 RAHNS RD., COLLEGEVILLE, PA 19426 (NAICS 327320). OSHA activity number 343939575.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- H&K GROUP, INC.
- Site address
- 430 RAHNS RD.
- City
- COLLEGEVILLE
- State
- PA
- ZIP
- 19426
- Mailing
- 2052 LUCON ROAD P.O. BOX 196, SKIPPACK, PA 19474
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327320
- Employees
- 36
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.36 G02
- Issued
- Jun 7, 2019
- Penalty
- Initial $6,137 · Current $0 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. a) Maintenance Building - on or about April 17, 2019, exit access was restricted with a forklift and chemicals stored in the storage room, the employer did not ensure exit access was at least 28 inches wide at all points.
Recent events (2)
- · I (S) $0
- · Z (S) $6137
5(a)(1)
- Issued
- Jun 7, 2019
- Penalty
- Initial $6,137 · Current $12,500
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees. a) Storage Area/Maintenance Bay - on or about April 17, 2019, employees transferred sand blast time release concrete converter/dissolver into workplace containers, but were not provided with suitable facilities for quick drenching or flushing of the eyes and body in the work area for immediate emergency use.
Recent events (2)
- · I (S) $12500
- · Z (S) $6137
1910.184 E01
- Issued
- Jun 7, 2019
- Penalty
- Initial $7,672 · Current $0 Reduced
General-duty citation text
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: a) Pre-Cast Building - on or about April 17, 2019, crane operators were lifting concrete forms with chains that did not have the identification affixed indicating the size, grade, and rated capacity.
Recent events (2)
- · I (O) $0
- · Z (S) $7672
1910.184 E03 II
- Issued
- Jun 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(e)(3)(ii): Records of the most recent month in which each alloy steel chain sling was thoroughly inspected were not available for examination: a) Pre-Cast Building - on or about April 17, 2019, employees were utilizing steel chain slings to lift concrete forms with overhead crane and the employer did not maintain records of when the slings were last thoroughly inspected.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G01 IV
- Issued
- Jun 7, 2019
- Abate by
- Jun 19, 2019
- Penalty
- Initial $4,603 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv): a) Pre-Cast Building - on or about April 17, 2019, an extension cord energized at 120 volts was being used to power forced air propane heaters and was attached to building walls and electrical conduit.
Recent events (2)
- · I (O) $0
- · Z (S) $4603
1910.334 A02 I
- Issued
- Jun 7, 2019
- Abate by
- Jun 19, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) Pre-Cast Building - on or about April 17, 2019, employees had not performed visual inspection on flexible extension cord for external defects prior to use with a portable heater.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.253 E06 II
- Issued
- Jun 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(e)(6)(ii): When regulators or parts of regulators, including gages, needed repair, the work was not performed by skilled mechanics who had been properly instructed: a) Welding Area/Pre-Cast Building - on or about April 17, 2019, an employee performed welding with oxygen cylinder with the inlet pressure gauge needing repair, and was not removed from service.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 F06
- Issued
- Jun 7, 2019
- Abate by
- Jun 19, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6): Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either: *The information specified under paragraphs (f)(1)(i) through (v) of this section for labels on shipped containers; or, *Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical. a) Storage Room/Maintenance Shop - on or about April 17, 2019, employees used anti-freeze for maintenance of vehicles placed into a workplace container, but was not properly labeled to include the pictures, symbols, or combinations thereof to provide general information regarding the hazards of the chemical within.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at H&K Group, INC.
View H&K Group, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327320)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343939575.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.