LYNDHURST, NJ ·
OSHA Inspection: CAMBRIDGE PAVERS INC
Fatality or catastrophe inspection · Safety discipline
At a glance
On , OSHA opened a fatality or catastrophe safety inspection of CAMBRIDGE PAVERS INC in 1 JEROME AVE, LYNDHURST, NJ 07071 (NAICS 327331). OSHA activity number 343945523.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAMBRIDGE PAVERS INC
- Site address
- 1 JEROME AVE
- City
- LYNDHURST
- State
- NJ
- ZIP
- 07071
- Mailing
- 1 JEROME AVE, LYNDHURST, NJ 07071
What kind of inspection was it?
- Inspection type
- Fatality or catastrophe (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327331
- Employees
- 150
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 17, 2019
- Penalty
- Initial $6,137 · Current $3,520 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazard from a mixer cover. a) Mixer Area: The Teka # 3 pan mixer hood that weighed up 100 pounds was lifted and held open with a hook that was not equipped with a safety latch. The hook was designed with a latch to prevent slings or load from accidentally slipping off the hook, on or about 4/22/2019.
Recent events (3)
- · F (S) $3520
- · C (S) $6137
- · Z (S) $6137
1910.110 E04 III
- Issued
- Oct 17, 2019
- Penalty
- Initial $4,602 · Current $4,602
General-duty citation text
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating: a) 1 Jerome Ave, Lyndhurst, NJ/On Roadway: Removable LPG cylinder on the Caterpillar powered industrial truck # 20, was missing the index pin necessary to securely mount the cylinder, on or about 4/22/2019.
Recent events (3)
- · F (O) $4602
- · C (S) $4602
- · Z (S) $4602
1910.147 C06 I
- Issued
- Oct 17, 2019
- Penalty
- Initial $7,672 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Mixer Area: The employer's energy control procedure for locking out the Teka Mixers for routine cleaning and maintenance was not inspected at least annually, on or about 4/19/2019.
Recent events (3)
- · F (S) $0
- · C (S) $7672
- · Z (S) $7672
1910.147 C04 I
- Issued
- Oct 17, 2019
- Penalty
- Initial $10,741 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Mixer Area: Energy control procedures were not utilized for the control of potentially hazardous energy. Employees manually cleaned the Teka Mixer #3 without locking or tagging it out, or otherwise controlling the potentially hazardous energy, on or about 4/19/2019.
Recent events (3)
- · F (S) $0
- · C (S) $10741
- · Z (S) $10741
1910.147 D04 I
- Issued
- Oct 17, 2019
- Penalty
- Initial $10,741 · Current $10,741
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees. a) Mixer Area: Employees were exposed to crushed-by hazards when they manually cleaned the Teka Mixer #3 without placing the mixer's energy isolation device(s) in the de-energized position and securing the energy isolating device(s) with a lockout or tagout device, on or about 4/19/2019.
Recent events (3)
- · F (S) $10741
- · C (S) $10741
- · Z (S) $10741
1910.305 B01 II
- Issued
- Oct 17, 2019
- Penalty
- Initial $6,137 · Current $6,137
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Mixer area/Teka Mixer 3: A 110 volt electrical box with an unused opening, exposed employees to an electrical shock and burns, on or about 4/22/2019. b) Mixer area/Teka Mixer 4: A 110 volt electrical box with an unused opening, exposed employees to an electrical shock and burns, on or about 4/22/2019.
Recent events (3)
- · F (S) $6137
- · C (S) $6137
- · Z (S) $6137
More inspections at Cambridge Pavers INC
View Cambridge Pavers INC's full OSHA safety record →
More inspections in this industry (NAICS 327331)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343945523.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.