CAZENOVIA, NY ·
OSHA Inspection: STK ELECTRONICS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of STK ELECTRONICS, INC. in 2747 ROUTE 20 EAST, CAZENOVIA, NY 13035 (NAICS 334416). OSHA activity number 343957890.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STK ELECTRONICS, INC.
- Site address
- 2747 ROUTE 20 EAST
- City
- CAZENOVIA
- State
- NY
- ZIP
- 13035
- Mailing
- 2747 ROUTE 20 EAST, CAZENOVIA, NY 13035
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334416
- Employees
- 30
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Sep 18, 2019
- Penalty
- Initial $4,508 · Current $2,705 Reduced
General-duty citation text
:29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created point of operation, rotating parts, and flying chips: a) Flex Con Assembly, on or about 4/25/19: Two Craftsman Drill Presses were not provided with a chuck and tool guard. b) Flex Con Assembly, on or about 4/25/19: Action Drill Press, model WTC-10 was not provided with a chuck and tool guard. c) Flex Con Assembly, on or about 4/25/19: Delta Drill Press was not provided with a chuck and tool guard. d) Maintenance Room, on or about 4/25/19: Jet Mill was not provided with a chuck and tool guard. e) Maintenance Room, on or about 4/25/19: Chicago Drill Press was not provided with a chuck and tool guard.
Recent events (2)
- · I (S) $2704.8
- · Z (S) $4508
1910.242 B
- Issued
- Sep 18, 2019
- Penalty
- Initial $3,381 · Current $2,029 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Maintenance Room, on or about 4/25/19: Employee used compressed air for cleaning purposes was measured at approximately 63 p.s.i.
Recent events (2)
- · I (S) $2028.6
- · Z (S) $3381
1910.304 G05
- Issued
- Sep 18, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous and effective: a) Flex Con Area, on or about 4/25/19: Metal Desk Lamp was not grounded in that it had only a two wire cord.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at STK Electronics, INC.
View STK Electronics, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334416)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343957890.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.