Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STK ELECTRONICS, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of STK ELECTRONICS, INC. in 2747 ROUTE 20 EAST, CAZENOVIA, NY 13035 (NAICS 334416). OSHA activity number 343957890.

Watch STK Electronics, INC. — free Get an email when a new federal OSHA severe-injury report for STK Electronics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2747 ROUTE 20 EAST
City
CAZENOVIA
State
NY
ZIP
13035
Mailing
2747 ROUTE 20 EAST, CAZENOVIA, NY 13035
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334416
Employees
30
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 5 instances 2 exposed
Issued
Penalty
Initial $4508.00 · Current $2705.00 Reduced
:29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created point of operation, rotating parts, and flying chips:    a)  Flex Con Assembly, on or about 4/25/19: Two Craftsman Drill Presses were not provided with a chuck and tool guard.    b) Flex Con Assembly, on or about 4/25/19:  Action Drill Press, model WTC-10 was not provided with a chuck and tool guard.    c) Flex Con Assembly, on or about 4/25/19:  Delta Drill Press was not provided with a chuck and tool guard.    d) Maintenance Room, on or about 4/25/19: Jet Mill was not provided with a chuck and tool guard.     e) Maintenance Room, on or about 4/25/19: Chicago Drill Press was not provided with a chuck and tool guard.
Recent events (2)
  • — I (S) $2704.8
  • — Z (S) $4508

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $3381.00 · Current $2029.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a) Maintenance Room, on or about 4/25/19: Employee used compressed air for cleaning purposes was measured at approximately 63 p.s.i.
Recent events (2)
  • — I (S) $2028.6
  • — Z (S) $3381

1910.304 G05

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous and effective:   a)  Flex Con Area, on or about 4/25/19: Metal Desk Lamp was not grounded in that it had only a two wire cord.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0