JACKSONVILLE, TX —
OSHA Inspection: LUMINANT GENERATION COMPANY, LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of LUMINANT GENERATION COMPANY, LLC in 1895 FM 2420 E, JACKSONVILLE, TX 75766 (NAICS 221112). OSHA activity number 343961207.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LUMINANT GENERATION COMPANY, LLC
- Site address
- 1895 FM 2420 E
- City
- JACKSONVILLE
- State
- TX
- ZIP
- 75766
- Mailing
- 1895 FM 2420 E, JACKSONVILLE, TX 75766
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221112
- Employees
- 21
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.179 B05
- Issued
- Oct 16, 2019
- Abate by
- Nov 12, 2019
- Penalty
- Initial $11,934 · Current $8,950 Reduced
General-duty citation text
29 CFR 1910.179(b)(5): The rated load of the crane was not plainly marked on each side of the crane, and if the crane has more than one hoisting unit, each hoist shall have its rated load marked on it or its load block and this marking shall be clearly legible from the ground or floor: (a) This violation occurred on April 24, 2019, where employee(s) assisting with the operation of the fifty (50) ton capacity Paceco Gantry Crane #184 were exposed to a crushed-by hazard in that the rated load of the crane was not plainly marked on each side of the crane or its load block. (b) This violation occurred on April 24, 2019, where employee(s) assisting with the operation of the 5 ton capacity Paceco Gantry Crane #184 were exposed to a crushed-by hazard in that the rated load of the crane was not plainly marked on each side of the crane or its load block.
Recent events (3)
- — F (O) $8950
- — C (S) $11934
- — Z (S) $11934
1910.179 E06 I
- Issued
- Oct 16, 2019
- Abate by
- Nov 12, 2019
- Penalty
- Initial $11,934 · Current $0 Reduced
General-duty citation text
29 CFR 1910.179(e)(6)(i): Exposed moving part(s) which might constitute a hazard under normal operating conditions were not guarded: (a) On or about April 23, 2019 employees walking/working on the catwalk located at the top of the Paceco gantry crane were exposed to a crushed-by hazard from the unguarded bridge drive wheels.
Recent events (3)
- — F (S) $0
- — C (S) $11934
- — Z (S) $11934
1910.303 E01 II
- Issued
- Oct 16, 2019
- Abate by
- Nov 12, 2019
- Penalty
- Initial $11,934 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(e)(1)(ii): Other markings giving voltage, current, wattage or other ratings as necessary: (a) On or about April 23, 2019 at Stryker Creek Natural Gas Fired Steam Electric Station located at 1895 CR 2420 E., Jacksonville, TX; on the junction box located on the 50-ton Paceco crane, where employees were exposed to an electrical hazard from an unmarked electrical junction box.
Recent events (3)
- — F (S) $0
- — C (S) $11934
- — Z (S) $11934
1910.335 A01 I
- Issued
- Oct 16, 2019
- Abate by
- Nov 12, 2019
- Penalty
- Initial $11,934 · Current $8,950 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: (a) This violation occurred on or about April 23, 2019 at the 50-ton Paceco Gantry Crane no. 184, where an employee working on a live electrical junction box with its cover removed was exposed to an electrical hazard in that he was not wearing personal protective equipment.
Recent events (3)
- — F (S) $8950
- — C (S) $11934
- — Z (S) $11934
More inspections at Luminant Generation Company, LLC
View Luminant Generation Company, LLC's full OSHA safety record →
More inspections in this industry (NAICS 221112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343961207.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.