Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KING KUTTER II

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KING KUTTER II in 2150 EASTERN AVE, GALLIPOLIS, OH 45631 (NAICS 336212). OSHA activity number 343978409.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch King Kutter II — free Get an email when a new federal OSHA severe-injury report for King Kutter II is published. One employer, no account, unsubscribe in one click.
Establishment
KING KUTTER II
Site address
2150 EASTERN AVE
City
GALLIPOLIS
State
OH
ZIP
45631
Mailing
P.O. BOX 786, GALLIPOLIS, OH 45631
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336212
Employees
70
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 I

Other-than-serious 1 instance 5 exposed
Issued
Aug 20, 2019
Abate by
Sep 23, 2019
Penalty
Initial $5,635 · Current $3,945 Reduced
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.    a. The employer did not conduct periodic inspection of energy control procedures when lockout tagout was used during servicing and maintenance of equipment.
Recent events (2)
  • — I (O) $3944.5
  • — Z (S) $5635

1910.184 I09 III

Other-than-serious 1 instance 5 exposed
Issued
Aug 20, 2019
Penalty
Initial $3,381 · Current $2,367 Reduced
29 CFR 1910.184(i)(9): Removal from service. Synthetic web slings shall be immediately removed from service if any of the following conditions are present:    29 CFR 1910.184(i)(9)(iii): Snags, punctures, tears or cuts.    a. In the welding area, yellow Redwing slings were found to have snags and cuts and were not taken out of service.
Recent events (2)
  • — I (O) $2366.7
  • — Z (S) $3381

1910.184 E01

Other-than-serious 1 instance 5 exposed
Issued
Aug 20, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.184(e)(1): Sling identification. Alloy steel chain slings shall have permanently affixed durable identification stating size, grade, rated capacity, and reach.  a. In the welding area, there was an alloy steel chain that was avaialbe for use and did not have identification attached to state the size, grad, rated capacity, and reach.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View King Kutter II's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343978409.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.