GALLIPOLIS, OH —
OSHA Inspection: KING KUTTER II
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KING KUTTER II in 2150 EASTERN AVE, GALLIPOLIS, OH 45631 (NAICS 336212). OSHA activity number 343978409.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KING KUTTER II
- Site address
- 2150 EASTERN AVE
- City
- GALLIPOLIS
- State
- OH
- ZIP
- 45631
- Mailing
- P.O. BOX 786, GALLIPOLIS, OH 45631
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336212
- Employees
- 70
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C06 I
- Issued
- Aug 20, 2019
- Abate by
- Sep 23, 2019
- Penalty
- Initial $5,635 · Current $3,945 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a. The employer did not conduct periodic inspection of energy control procedures when lockout tagout was used during servicing and maintenance of equipment.
Recent events (2)
- — I (O) $3944.5
- — Z (S) $5635
1910.184 I09 III
- Issued
- Aug 20, 2019
- Penalty
- Initial $3,381 · Current $2,367 Reduced
General-duty citation text
29 CFR 1910.184(i)(9): Removal from service. Synthetic web slings shall be immediately removed from service if any of the following conditions are present: 29 CFR 1910.184(i)(9)(iii): Snags, punctures, tears or cuts. a. In the welding area, yellow Redwing slings were found to have snags and cuts and were not taken out of service.
Recent events (2)
- — I (O) $2366.7
- — Z (S) $3381
1910.184 E01
- Issued
- Aug 20, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(e)(1): Sling identification. Alloy steel chain slings shall have permanently affixed durable identification stating size, grade, rated capacity, and reach. a. In the welding area, there was an alloy steel chain that was avaialbe for use and did not have identification attached to state the size, grad, rated capacity, and reach.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at King Kutter II
View King Kutter II's full OSHA safety record →
More inspections in this industry (NAICS 336212)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343978409.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.