LE ROY, NY —
OSHA Inspection: ORCON INDUSTRIES, CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ORCON INDUSTRIES, CORP. in 8715 LAKE ROAD, LE ROY, NY 14482 (NAICS 322211). OSHA activity number 343982195.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ORCON INDUSTRIES, CORP.
- Site address
- 8715 LAKE ROAD
- City
- LE ROY
- State
- NY
- ZIP
- 14482
- Mailing
- 8715 LAKE ROAD, LE ROY, NY 14482
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322211
- Employees
- 60
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 A01
- Issued
- Jun 3, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $5,304 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment were not kept in a clean condition: a) On or about 05/06/19 in Plant 2 Woodworking shop; employees were exposed to potential fire hazard when wood dust and pieces of wood were piled to a height of 30 inches, 42 inches wide and 10 feet in length in the area below the Verticut 2000 saw table due to the lack of a dumpster to discard the wood coupled with the dust collector system for this saw not functioning properly. b) On or about 05/06/19 in Plant 2 Woodworking shop; employees were exposed to potential fire hazard when wood dust was clearly visible to a depth of 1/4 inch behind the Verticut 2000 saw table, plied to a height of 3-6 inches up a support beam and piled on top of a drum of bar chain oil due to the lack of a dumpster to discard the material and the dust collector system for this saw not functioning properly. c) On or about 05/06/19 in Plant 2 Woodworking shop; employees were exposed to a potential fire hazard when a pile of wood dust approximately 2 feet in diameter and nearly two feet high was observed on the mezzanine for the plant dust collector blower motors. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3000
- — Z (S) $5304
1910.147 C04 I
- Issued
- Jun 3, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $6,630 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 05/24/19 in the Production area; during change over and set up of the vacuum former machines, employee were exposed to caught between hazards of the platens when they relied on the safety interlocked access doors for energy isolation instead of applying locks to the energy isolation devices. b) On or about 05/24/29 in the Saw area; during the set up of the Bruno Die Cutter, employees were exposed to caught between hazards of the upper portion of the die cutter ram when they opened safety interlocked guard to access the height adjustment devices instead of applying locks to the energy isolation device as described in the Bruno Die Cutter Lock out procedure posted on the machine. c) On or about 05/24/19 in the Production area; during the dislodging of the jams through the lower door on the foam densifiers, employees were exposed to being caught in the auger when they relied on the open safety interlocked lower door instead of applying a lock to the energy isolation device. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $4000
- — Z (S) $6630
1910.147 C07 I A
- Issued
- Jun 3, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $6,630 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation; a) On or about 05/24/19 in the Production area; during change over and set up of the vacuum former machines, employee were exposed to caught between hazards of the platens when they relied on the safety interlocked access doors for energy isolation and trained to the Affected level under this Standard. b) On or about 05/24/29 in the Saw area; during the set up of the Bruno Die Cutter, employees were exposed to caught between hazards of the upper portion of the die cutter ram when they opened safety interlocked guard for energy isolation to access the height adjustment devices instead of applying locks to the energy isolation device as described in the Bruno Die Cutter Lock out procedure posted on the machine and trained to the Affected level under this Standard. c) On or about 05/24/19 in the Production area; during the dislodging of the jams through the lower door on the foam densifiers, employees were exposed to being caught in the auger when they relied on the open safety interlocked lower door instead of applying a lock to the energy isolation device and trained to the Affected level under this Standard. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $4000
- — Z (S) $6630
1910.305 B02 I
- Issued
- Jun 3, 2019
- Penalty
- Initial $3,381 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose; a) On or about 05/24/19 on the Thermo Former; employees were exposed to contact with electrical current when the junction box on the feed spool was missing a cover exposing bare wires. b) On or about 05/06/19 on the Thermo Former; employees were exposed to contact with electrical current when the cover to the junction box located on the north side of the machine frame was not secured. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2500
- — Z (S) $3381
1910.303 B02
- Issued
- Jun 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about 05/24/19 near the Thermo Former; employees were exposed to fire hazard when the employer allowed the use of a two relocatable power taps daisy chained to provide power to a battery charger. One power tap was plugged into an extension cord that was pulled into another power tap that was plugged into another extension cord that was plugged into an outlet. The second power tap was secured to one leg of a small table with two plastic ties. b) On or about 05/24/19 near the Bruno die cutter; employees were exposed to a fire hazard when the employer allowed the use of a relocated power tap, secured to a metal frame of a work table with two plastic ties, to provide power for a battery charger. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Jun 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) On or about 05/24/19 near the Thermo Former; employees were exposed to fire hazard when the employer allowed the use of a two extension cords to daisy chain and provide power to two relocateable power taps. An extension cord from a power tap on the work table on the east side of the machine was plugged into an extension cord which ran overhead and was snaked around a wiring control support arm of the Thermo Former, across the machine and down to another power tap where a second extension cord was used to provide power to the second power tap. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Orcon Industries, Corp.
View Orcon Industries, Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 322211)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343982195.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.