Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KAYSUN CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KAYSUN CORPORATION in 5500 WEST DRIVE, MANITOWOC, WI 54220 (NAICS 326199). OSHA activity number 343991964.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kaysun Corporation — free Get an email when a new federal OSHA severe-injury report for Kaysun Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
KAYSUN CORPORATION
Site address
5500 WEST DRIVE
City
MANITOWOC
State
WI
ZIP
54220
Mailing
5500 WEST DRIVE, MANITOWOC, WI 54220
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
240
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 5, 2019
Penalty
Initial $7,246 · Current $5,072 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.     On or about May 1, 2019, Kaysun Corporation had not developed a specific procedure to control hazardous energy sources when employees are conducting maintenance and service activities on the automatic bearing loader near Press #77.      Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.
Recent events (2)
  • — I (S) $5072.2
  • — Z (S) $7246

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  On or about May 8, 2019, Kaysun Corporation had not completed a Periodic Inspection of it's specific procedures for controlling hazardous energy sources within the previous twelve months.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 5, 2019
Penalty
Initial $5,796 · Current $4,057 Reduced
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.    On or about May 8, 2019, electrical panels in the shop area were blocked by cart and welding equipment.
Recent events (2)
  • — I (S) $4057.2
  • — Z (S) $5796

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.  On or about May 8, 2019, a flexible cord for the resin vacuum on Press #77 did not provide strain relief preventing damage to the cable or preventing it from pulling free of the connector.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 II

Other-than-serious 1 instance 2 exposed
Issued
Aug 5, 2019
Abate by
Sep 3, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(ii): The physical, health, simple asphyxiation, combustible dust, and pyrophoric gas hazards, as well as hazards not otherwise classified, of the chemicals in the work area;  On or about May 8, 2019, employees had not been trained in the specific hazards of chemicals in their work area such as Molders Choice Mold Cleaner.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Kaysun Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343991964.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.