Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CAPITAL INDUSTRIAL COATINGS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CAPITAL INDUSTRIAL COATINGS, LLC in I-294 & I-90, ROSEMONT, IL 60018 (NAICS 238320). OSHA activity number 344014675.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Capital Industrial Coatings, LLC — free Get an email when a new federal OSHA severe-injury report for Capital Industrial Coatings, LLC is published. One employer, no account, unsubscribe in one click.
Site address
I-294 & I-90
City
ROSEMONT
State
IL
ZIP
60018
Mailing
141 EAST 141ST ST, HAMMOND, IN 46327
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.404 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Nov 4, 2019
Penalty
Initial $3,031 · Current $2,000 Reduced
29 CFR 1926.404(b)(1)(ii):  Where an assured equipment grounding program was not utilized, receptacles were not protected with ground fault circuit interrupters when on a two-wire, single- phase portable or vehicle-mounted generator rated more than 5kW, or where the circuit conductors of the generator were not insulated from the generator frame and all other grounded surfaces:      a)  On May 14, 2019, employees were provided and used a 120 Volt, Honda EU3000is Portable Generator with receptacles not protected with ground fault circuit interrupters to power equipment and tools onsite.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $3031

1926.451 G01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 4, 2019
Abate by
Nov 8, 2019
Penalty
Initial $3,789 · Current $2,774 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level:    a)  On May 14, 2019, employees were exposed to hazards of falling approximately 40 feet to the ground during the transfers between an elevated aerial lift platform and the Safespan under-the-bridge suspended platform.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2774
  • — Z (S) $3789

1926.502 D20

Other-than-serious 1 instance 6 exposed
Issued
Nov 4, 2019
Abate by
Dec 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(20): The employer did not provide for prompt rescue of employees in the event of a fall or did not assure that employees were able to rescue themselves:  a)  On or about May 14, 2019, the employer did not implement and maintain a rescue plan in the event of a fall into a live highway traffic from the Safeway under-the-bridge platform.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.502 D01

Other-than-serious 1 instance 1 exposed
Issued
Nov 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(1): Personal fall arrest system connectors were not drop forged, pressed or formed steel, or made of equivalent materials:      a) On May 14, 2019, employees were exposed to fall hazards of approximately 40 feet to the ground while using personal fall arrest system components containing connectors that were not drop forged, pressed or formed steel.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Capital Industrial Coatings, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344014675.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.