HOUSTON, TX —
OSHA Inspection: NIALTI MANUFACTURING, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NIALTI MANUFACTURING, LLC in 12018 PALMERTON DR., HOUSTON, TX 77064 (NAICS 326299). OSHA activity number 344032099.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NIALTI MANUFACTURING, LLC
- Site address
- 12018 PALMERTON DR.
- City
- HOUSTON
- State
- TX
- ZIP
- 77064
- Mailing
- 12018 PALMERTON DR., HOUSTON, TX 77064
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326299
- Employees
- 8
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jun 14, 2019
- Abate by
- Aug 9, 2019
- Penalty
- Initial $3,978 · Current $1,989 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about May 22, 2019, and times prior thereto: a. In Bay #1, where employees were exposed to electrical shock and struck-by hazards when servicing a 4-post hydraulic press, ID #1 without procedures for the control of potentially hazardous energy. b. In Bay #1, where employees were exposed to electrical shock and struck-by hazards when servicing a 4-post hydraulic press, ID #3 without procedures for the control of potentially hazardous energy. c. In Bay #1, where employees were exposed to electrical shock and struck-by hazards when servicing a 4-post hydraulic press, ID #5 without procedures for the control of potentially hazardous energy. d. In Bay #1, where employees were exposed to electrical shock and struck-by hazards when servicing a 4-post hydraulic press, ID #6 without procedures for the control of potentially hazardous energy. e. In Bay #1, where employees were exposed to electrical shock and struck-by hazards when servicing a 4-post hydraulic press, ID #7 without procedures for the control of potentially hazardous energy. f. In Bay #1, where employees were exposed to electrical shock and struck-by hazards when servicing a 4-post hydraulic press, ID #9 without procedures for the control of potentially hazardous energy. g. In Bay 1#, where employees were exposed to electrical shock and struck-by hazards when servicing a 4-post hydraulic press, ID #10 without procedures for the control of potentially hazardous energy. h. In Bay #1, where employees were exposed to electrical shock and struck-by hazards when servicing a 4-post hydraulic press, ID #13 without procedures for the control of potentially hazardous energy.
Recent events (2)
- — I (S) $1989
- — Z (S) $3978
1910.147 C05 I
- Issued
- Jun 14, 2019
- Abate by
- Jul 12, 2019
- Penalty
- Initial $3,978 · Current $1,989 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: On or about May 22, 2019, and times prior thereto, where employees in Bay #1 where employees were exposed to electrical shock and struck-by hazards when servicing hydraulic presses without locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware to isolate the machines from energy sources.
Recent events (2)
- — I (S) $1989
- — Z (S) $3978
1910.212 A03 II
- Issued
- Jun 14, 2019
- Abate by
- Jul 26, 2019
- Penalty
- Initial $2,842 · Current $1,421 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): On or about May 22, 2019, and times prior thereto: a. In Bay #1, where employees were exposed to struck-by hazards when operating a 4-post hydraulic press, ID #1 without point of operation guarding. b. In Bay #1, where employees were exposed to struck-by hazards when operating a 4-post hydraulic press, ID #3 without point of operation guarding. c. In Bay #1, where employees were exposed to struck-by hazards when operating a 4-post hydraulic press, ID #5 without point of operation guarding. d. In Bay #1, where employees were exposed to struck-by hazards when operating a 4-post hydraulic press, ID #6 without point of operation guarding. e. In Bay #1, where employees were exposed to struck-by hazards when operating a 4-post hydraulic press, ID #7 without point of operation guarding. f. In Bay #1, where employees were exposed to struck-by hazards when operating a 4-post hydraulic press, ID #9 without point of operation guarding. g. In Bay #1, where employees were exposed to struck-by hazards when operating a 4-post hydraulic press, ID #10 without point of operation guarding. h. In Bay #1, where employees were exposed to struck-by hazards when operating a 4-post hydraulic press, ID #13 without point of operation guarding. i. In Bay #3, where employees were exposed to struck-by hazards when operating a Bridgepoint Mill S/N 265778 without point of operation guarding.
Recent events (2)
- — I (S) $1421
- — Z (S) $2842
1910.303 G02 I
- Issued
- Jun 14, 2019
- Abate by
- Jul 26, 2019
- Penalty
- Initial $3,978 · Current $1,989 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On or about May 22, 2019, and times prior thereto: a. In Bay #1, where employees were exposed to electrical shock hazards when operating a 240 VAC 4-post hydraulic press, ID #1 without guarding against accidental contact by use of approved enclosures or other means. b. In Bay #1, where employees were exposed to electrical shock hazards when operating a 240 VAC 4-post hydraulic press, ID #3 without guarding against accidental contact by use of approved enclosures or other means. c. In Bay #1, where employees were exposed to electrical shock hazards when operating a 240 VAC 4-post hydraulic press, ID #5 without guarding against accidental contact by use of approved enclosures or other means. d. In Bay #1, where employees were exposed to electrical shock hazards when operating a 240 VAC 4-post hydraulic press, ID #6 without guarding against accidental contact by use of approved enclosures or other means. e. In Bay #1, where employees were exposed to electrical shock hazards when operating a 240 VAC 4-post hydraulic press, ID #7 without guarding against accidental contact by use of approved enclosures or other means. f. In Bay #1, where employees were exposed to electrical shock hazards when operating a 240 VAC 4-post hydraulic press, ID #9 without guarding against accidental contact by use of approved enclosures or other means. g. In Bay #1, where employees were exposed to electrical shock hazards when operating a 240 VAC 4-post hydraulic press, ID #10 without guarding against accidental contact by use of approved enclosures or other means. h. In Bay #1, where employees were exposed to electrical shock hazards when operating a 240 VAC 4-post hydraulic press, ID #13 without guarding against accidental contact by use of approved enclosures or other means. i. In Bay #1, where employees were exposed to electrical shock hazards when operating a 240 VAC hydraulic pump motor without guarding against accidental contact by use of approved enclosures or other means.
Recent events (2)
- — I (S) $1989
- — Z (S) $3978
1910.132 D02
- Issued
- Jun 14, 2019
- Abate by
- Jul 12, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: On or about May 22, 2019, and times prior thereto, employees operated industrial equipment, handled chemicals, and applied paints without the verification through written certification that the required workplace hazard assessment had been performed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C01
- Issued
- Jun 14, 2019
- Abate by
- Jul 19, 2019
- Penalty
- Initial $319 · Current $160 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about May 22, 2019, and times prior thereto, employees were required to use respiratory protection without worksite specific procedures being implemented.
Recent events (2)
- — I (O) $159.5
- — Z (O) $319
1910.147 C07 IV
- Issued
- Jun 14, 2019
- Abate by
- Aug 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certified that employee training had been accomplished: On or about May 22, 2019 and times prior thereto, employees serviced hydraulic presses without certification that training in hazardous energy control had been accomplished.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L06
- Issued
- Jun 14, 2019
- Abate by
- Aug 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): On or about May 22, 2019, and times prior thereto, throughout the facility where employees operated a Hyundai Forklift, Model 30D-9 without certification that operators had been trained and evaluated.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Nialti Manufacturing, LLC
View Nialti Manufacturing, LLC's full OSHA safety record →
More inspections in this industry (NAICS 326299)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344032099.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.