MONETT, MO —
OSHA Inspection: PLAY POWER, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PLAY POWER, INC. in 878 E US HWY 60, MONETT, MO 65708 (NAICS 339920). OSHA activity number 344037254.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PLAY POWER, INC.
- Site address
- 878 E US HWY 60
- City
- MONETT
- State
- MO
- ZIP
- 65708
- Mailing
- 878 E US HWY 60, MONETT, MO 65708
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339920
- Employees
- 500
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.28 B07
- Issued
- Oct 4, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $9,472 · Current $0 Reduced
General-duty citation text
29 CFR 1910.28(b)(7): 1910.28(b)(7): The employer did not ensure that each employee on a walking-working surface near an opening, including one with a chute attached, where the inside bottom edge of the opening is less than 39 inches (99 cm) above that walking-working surface and the outside bottom edge of the opening is 4 feet (1.2 m) or more above a lower level is protected from falling: Employees were exposed to fall hazards. The West Plant platforms such as, Platform 330, with slides used to slide the playground equipment down from the platform to ground did not have a standard guardrail. The platform had one top rail chain but no midrail chain.
Recent events (2)
- — I (S) $0
- — Z (S) $9472
1910.178 P01
- Issued
- Oct 4, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $7,577 · Current $5,304 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): Forklift operators were exposed to struck by hazards. Employee were exposed to the Yale Propane forklift E #13, and Yale Propane Forklift # E76, both did not have a nonslip surface on the brake pedal and were not taken out of service until they were repaired.
Recent events (2)
- — I (O) $5303.9
- — Z (S) $7577
1910.212 A01
- Issued
- Oct 4, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $9,472 · Current $6,630 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Employees were exposed to amputation hazards. Employees working in the Fab Area were exposed to the Wilton VSG Twenty Model No. 2025, Asset F330 Drill Press which did not have a chuck guard. (b) Employees were exposed to amputation hazards. Employees working in the Fab Area were exposed to the Wilton VSG 20 Pine Drill Asset F362 which did not have a chuck guard. (c) Employees were exposed to amputation hazards. Employees working in the PVC Fab Area were exposed to the Accurshear which the guard did not adequately guard the hold downs, and the shear blade.
Recent events (2)
- — I (S) $6630.4
- — Z (S) $9472
1910.212 A05
- Issued
- Oct 4, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $7,577 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: Employees were exposed to amputation hazards. Employees working in the West Plant EZ- Dock were exposed to the Port A Cool which had greater than 1/2 inch openings in the guard for the fan blades.
Recent events (2)
- — I (S) $0
- — Z (S) $7577
1910.215 A04
- Issued
- Oct 4, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $7,577 · Current $5,304 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: Employees were exposed to struck by hazards from the grinding wheel. Employees were using the Craftsman Bench Grinder in the Mold Maintenance Department. The left wheel facing the the bench grinder did not have the work rest adjusted to an 1/8 inch or less.
Recent events (2)
- — I (S) $5303.9
- — Z (S) $7577
1910.215 B09
- Issued
- Oct 4, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: Employees were exposed to struck by hazards. Employees were exposed to the Craftsman Bench Grinder in the Mold Maintenance Department which did not have an adjustable tongue guard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.217 C02 I A
- Issued
- Oct 4, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $9,472 · Current $6,630 Reduced
General-duty citation text
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s): Employees were exposed to amputation hazards. The Federal F8 Asset # F343 100 ton mechanical power press had an opening in the guard in the right side above where the material is being fed into the press. It had a large enough hole that it did not prevent entry of hands or fingers from reaching through the guard.
Recent events (2)
- — I (S) $6630.4
- — Z (S) $9472
1910.217 C02 I D
- Issued
- Oct 4, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $9,472 · Current $0 Reduced
General-duty citation text
29 CFR 1910.217(c)(2)(i)(d): Point of operation guard(s) on mechanical power press(es) did not utilized fasteners not readily removable by the operator, so as to create minimize the possibility of misuse or removal of essential parts: Employees were exposed to amputation hazards. The Federal F8 Asset #F343 100 ton mechanical power press had a flap in the front that had a swinging latch instead of fasteners not readily removable by the operator.
Recent events (2)
- — I (S) $0
- — Z (S) $9472
1910.219 B01
- Issued
- Oct 4, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $9,472 · Current $6,630 Reduced
General-duty citation text
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv)(a): Employees were exposed to amputation hazards. The Iowa Machinery Supply Company vertical band saw in the Maintenance Shop had a portion of the flywheel which was unguarded. The flywheel was not fully guarded within seven feet of the floor.
Recent events (2)
- — I (S) $6630.4
- — Z (S) $9472
1910.303 B01 II
- Issued
- Oct 4, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $7,577 · Current $5,304 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: (a) Employees were exposed to electrical hazards. The Johnson 60 Punch Press, Asset # F374, had a two hand control that had a missing knockout. (b) Employees in the Mold Maintenance Department were exposed to electrical hazards. The Siemens 240 electrical breaker next to the lathe had two open knockouts on the left side.
Recent events (2)
- — I (S) $5303.9
- — Z (S) $7577
1910.303 G02 I
- Issued
- Oct 4, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $9,472 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): (a) Employees were exposed to electrical hazards. Employees were exposed to electrical wiring for a light attached to the Iowa Machinery Supply Company vertical bandsaw which was 110/120 volts which was connected with wire nuts and not guarded by a cabinet or enclosure. (b) Employees were exposed to electrical hazards. Employees were exposed to electrical wiring as the Dock light to the right of Dock Door # 2 was hanging loose from the fixture and the fixture was broken exposing employees to live wiring which was 110/120 volts. (c) Employees were exposed to electrical hazards. Employees were exposed to electrical wiring as the Dock light by Dock Door # 3 was hanging loose from the fixture exposing employees to live wiring which was 110/120 volts.
Recent events (2)
- — I (S) $0
- — Z (S) $9472
More inspections at Play Power, INC.
View Play Power, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 339920)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344037254.