WILLIAMSTOWN, WV —
OSHA Inspection: CARR CONCRETE A DIVISION OF CXT INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CARR CONCRETE A DIVISION OF CXT INCORPORATED in 362 WAVERLY ROAD, WILLIAMSTOWN, WV 26187 (NAICS 327390). OSHA activity number 344043344.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARR CONCRETE A DIVISION OF CXT INCORPORATED
- Site address
- 362 WAVERLY ROAD
- City
- WILLIAMSTOWN
- State
- WV
- ZIP
- 26187
- Mailing
- PO BOX 265, WAVERLY, WV 26184
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 101
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Jul 10, 2019
- Abate by
- Jul 29, 2019
- Penalty
- Initial $5,115 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Building 5, Fabrication Area: On May 29, 2019 and times prior to, the employer did not provide machine guarding for a Craftsman 20 inch drill press (model #113.213213, serial #9701400040) to protect employees from the rotating chuck and unused portion of the bit.
Recent events (2)
- — I (S) $3500
- — Z (S) $5115
1910.147 C06 I
- Issued
- Jul 10, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: (a) Building 8, Batch Plant Mixer: On May 29, 2019 and times prior, the employer did not conduct an annual periodic inspection between an inspector and authorized employee to ensure that the employee(s) followed the energy control procedures for the, but not limited to, the batch plant mixer has two electrical energy sources; 480 volt electrical.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Carr Concrete a Division of CXT Incorporated
View Carr Concrete a Division of CXT Incorporated's full OSHA safety record →