AUSTELL, GA —
OSHA Inspection: PABB CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PABB CORPORATION in 7190 DELTA CIRCLE, AUSTELL, GA 30168 (NAICS 811118). OSHA activity number 344072319.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PABB CORPORATION
- Site address
- 7190 DELTA CIRCLE
- City
- AUSTELL
- State
- GA
- ZIP
- 30168
- Mailing
- 7190 DELTA CIRCLE, AUSTELL, GA 30168
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811118
- Employees
- 22
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.212 A03 II
- Issued
- Nov 1, 2019
- Abate by
- Nov 29, 2019
- Penalty
- Initial $3,031 · Current $1,819 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. a) Driveline Shop: On or about June 11, 2019 , and times prior, employer exposed employees to caught-in hazards in that a Summit Lathe (Model 19-4x80 S/N 5308) had a rotating chuck which was not guarded. b) Spring Shop: On or about June 11, 2019 and at times prior, employees were exposed to caught-in hazards, in that machine guarding was not installed on the Powermatic Drill Press Model PW28008 Serial Number 3884-3 while employees were drilling holes on metal parts.
Recent events (2)
- — I (S) $1818.6
- — Z (S) $3031
1910.215 A04
- Issued
- Nov 1, 2019
- Penalty
- Initial $1,932 · Current $1,159 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion. a) Driveline Shop, East Wall: On or about June 11, 2019, and at times prior, the employer exposed employees to struck-by and caught-in hazards while using a Sunex Bench Grinder Model 5001A (No Serial Number), which had the tool rest adjusted to one half inch from the wheel.
Recent events (2)
- — I (S) $1159.2
- — Z (S) $1932
1910.215 B09
- Issued
- Nov 1, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Exposure adjustment. Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. a) Driveline Shop, East Wall: On or about June 11, 2019, and at times prior, the employer exposed employees to struck-by and caught-in hazards while using a Sunex Bench Grinder Model 5001A (No Serial Number), in which the tongue was not adjusted to a maximum opening of one-fourth inch to the wheel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.243 C01 II A
- Issued
- Nov 1, 2019
- Penalty
- Initial $3,031 · Current $1,819 Reduced
General-duty citation text
29 CFR 1910.243(c)(1)(ii)(a): A safety guard shall cover the spindle end, nut and flange projections. The safety guard shall be mounted so as to maintain proper alignment with the wheel, and the strength of the fastenings shall exceed the strength of the guard. a) Bay Area: On or about June 11, 2019 and at times prior, employees were exposed to struck-by hazards, in that a Milwaukee Hand Grinder Model had its guard removed.
Recent events (2)
- — I (S) $1818.6
- — Z (S) $3031
1910.254 D09 III
- Issued
- Nov 1, 2019
- Penalty
- Initial $2,273 · Current $1,364 Reduced
General-duty citation text
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors shall be replaced. Joining lengths of work and electrode cables shall be done by the use of connecting means specifically intended for the purpose. The connecting means shall have insulation adequate for the service conditions. a) Driveline Shop, Welding Area: On or about June 11, 2019, and at times prior, the employer exposed an employee to electrical shock and burn hazards in that the grounding cable of the Miller Welder (Model Deltaweld 302 S/N ZD-MMF520062C) had frayed insulation.
Recent events (2)
- — I (S) $1363.8
- — Z (S) $2273
1910.23 C01
- Issued
- Nov 1, 2019
- Abate by
- Nov 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides. a) Front Wheel Alignment Pit: On or about June 11, 2019, and times prior, the employer exposed employees to fall hazards of approximately 5 feet (62 inches) by not properly guarding the pit with guardrails or providing fall protection to employees working in the area.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L02 II
- Issued
- Nov 1, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(2)(ii): Training shall consist of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. a) Throughout facility: On or about June 11, 2019, and at times prior, the employer exposed employees to struck-by hazards by allowing the Powered Industrial Truck operators to operate a Forklift (Mitsubishi Model FG25 Serial Number AF17B01192) without proper training certification.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L06
- Issued
- Nov 1, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation. a) Throughout facility: On or about April 13, 2017, and at times prior, the employer exposed employees to struck-by hazards by allowing the Powered Industrial Truck operators to operate a Forklift (Mitsubishi Model FG25 Serial Number AF17B01192) , prior to receiving their training certification.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 P01
- Issued
- Nov 1, 2019
- Abate by
- Nov 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition. a) Warehouse: On or about May 04, 2018, and at times prior, the employer exposed employees to struck-by hazards in that Forklift (Mitsubishi Model FG25 Serial Number AF17B01192) had a frayed hydraulic hose located at the mast but was not taken out of service.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 Q07
- Issued
- Nov 1, 2019
- Abate by
- Nov 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected. a) Throughout facility: On or about March 29, 2018, and at times prior, the employer exposed employees to struck-by hazards by allowing the Powered Industrial Truck operators to operate a Forklift (Mitsubishi Model FG25 Serial Number AF17B01192), without performing a pre-operational inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.253 B02 II
- Issued
- Nov 1, 2019
- Abate by
- Nov 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards. a) Driveline Shop, East Wall: On or about June 11, 2019, and at times prior, the employer exposed employees to struck-by hazards, in that Argon, Acetylene, and Oxygen cylinders were not properly secured. b) Spring Shop, East Wall: On or about June 11, 2019, and at times prior, the employer exposed employees to struck-by hazards, in that Argon and Oxygen cylinders were not properly secured.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Nov 1, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables may not be used as a substitute for the fixed wiring of a structure. a) Driveline Shop, West Wall: On or about June 11, 2019, and at times prior, the employer exposed employees to electrical shock and fire hazards while utilizing a fan that was connected to an extension cord and tied to the building structure.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Pabb Corporation