Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: H&W CONTRACTING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of H&W CONTRACTING, LLC in INTERSECTION 69TH & MEDICAL COURT, SIOUX FALLS, SD 57107 (NAICS 237110). OSHA activity number 344074695.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch H&W Contracting, LLC — free Get an email when a new federal OSHA severe-injury report for H&W Contracting, LLC is published. One employer, no account, unsubscribe in one click.
Site address
INTERSECTION 69TH & MEDICAL COURT
City
SIOUX FALLS
State
SD
ZIP
57107
Mailing
3416 WEST HOVLAND DRIVE, SIOUX FALLS, SD 57107
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.652 A01

Other-than-serious 3 instances 2 exposed
Issued
Sep 9, 2019
Abate by
Oct 3, 2019
Penalty
Initial $3,031 · Current $3,031
29 CFR 1926.651(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):      (a)H&W Contracting, LLC at 69th Street & Medical Court Sioux Falls, SD 57107:  On or about and at times prior to June 12, 2019, the exposing employer did not ensure employees were protected from cave-in and struck-by hazards while working within an excavation deeper than five feet. An employee jumped down into an area of the excavation located above the trench box, which was greater than five feet in depth and unprotected, within an excavation approximately 13 feet in depth. The employee accessed the excavation to provide a grinder to an employee working within a trench box. The condition exposed an employee to a cave-in and struck-by hazard associated with accessing an unprotected area above a trench box located within the excavation.
Recent events (2)
  • — I (O) $3031
  • — Z (S) $3031

1926.651 K01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Sep 9, 2019
Abate by
Oct 3, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems:  (a)H&W Contracting, LLC at 69th Street & Medical Court Sioux Falls, SD 57107:  On or about and at times prior to June 12, 2019, the exposing employer did not ensure that daily inspections of a trench that was approximately 13 feet in depth were made by the competent person for evidence of a situation that could have resulted in a hazardous condition. The competent person did not identify that the trench was greater than five feet in depth, had near vertical walls on the east and west ends, was undercut on the west end near the bottom and had a gap of approximately 2 feet between the inner wall of the trench box and the plate steel shield on the east end. This condition exposed employees to struck-by hazards and crushing injuries associated with trench wall cave-in.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B04

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Sep 9, 2019
Abate by
Oct 3, 2019
Penalty
Initial $3,031 · Current $0 Reduced
29 CFR 1926.1053(b)(4):  Ladders were used for purposes other than the purposes for which they were designed:     (a)H&W Contracting, LLC at 69th Street, Sioux Falls, SD 57107:  On or about June 12, 2019, the employer did not ensure employees were using a Louisville extension ladder for the purposes for which they were designed. An employee was utilizing the top section of an extension ladder to access and egress from a trench box. The manufacturer specifically indicates that it is unsafe to use the top section of an extension ladder based on the section was not equipped with feet to stabilize the ladder. This condition exposed employees to a fall hazard of approximately 12 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3031

View H&W Contracting, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344074695.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.