OSHA Inspection: HI-RISE CRANE, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of HI-RISE CRANE, INC. in 6320 SW 8TH STREET SOLESTE ALAMEDA 1, MIAMI, FL 33101 (NAICS 333923). OSHA activity number 344096433.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hi-Rise Crane, INC. — free Get an email when a new federal OSHA severe-injury report for Hi-Rise Crane, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
HI-RISE CRANE, INC.
Site address
6320 SW 8TH STREET SOLESTE ALAMEDA 1
City
MIAMI
State
FL
ZIP
33101
Mailing
1900 N.W. 22ND STREET, FORT LAUDERDALE, FL 33310
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333923
Employees
26
Ownership type
A

8 citations on file for this inspection.

1926.1408 A02

Serious Gravity 10 2 instances 1 exposed
Issued
Oct 18, 2019
Abate by
Nov 30, 2019
Penalty
Initial $9,282 · Current $6,497 Reduced
29 CFR 1926.1408(a)(2): The employer did not determine if any part of the equipment, load line or load (including rigging and lifting accessories), if operated up to the equipment's maximum working radius in the work zone, could get closer than 20 feet to a power line. If so, the employer must meet the requirements in Option (1), Option (2), or Option (3) of this section, as follows:    On or about April 22, 2019, at 6320 SW 8th Street, Miami, Florida, 33101, employees were exposed to an electrocution hazard while a tower crane was being operated with its load line and load located at a distance closer than 20 feet from energized electrical lines.       NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $6497
  • — Z (S) $9282

1926.1408 A02 I

Serious Gravity 10 2 instances 1 exposed
Issued
Oct 18, 2019
Abate by
Nov 14, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1408(a)(2)(i): Option (1)--Deenergize and ground. The employer did not determine if any part of the equipment, load line or load (including rigging and lifting accessories), if operated up to the equipment's maximum working radius in the work zone, could get closer than 20 feet to a power line. If so, the employer must meet the requirements in Option (1), Option (2), or Option (3) of this section, as follows:  On or about April 22, 2019, at 6320 SW 8th Street, Miami, Florida, 33101, the employer failed to ensure de-energization and grounding of electrical utilities while a tower crane was operating with its load line and load near energized electrical power lines, thus exposing employees to an electrocution hazard.   NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1408 A02 II

Serious Gravity 10 2 instances 1 exposed
Issued
Oct 18, 2019
Abate by
Nov 14, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1408(a)(2)(ii): Option (2)--20 foot clearance. The employer failed to ensure that no part of the equipment, load line, or load (including rigging and lifting accessories), gets closer than 20 feet to the power line by implementing the measures specified in paragraph (b) of this section:  On or about April 22, 2019, at 6320 SW 8th Street, Miami, Florida, 33101, the employer failed to ensure a load line and load for a tower crane were kept further away than 20 feet from power lines, thus exposing employees to an electrocution hazard.  NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1408 A02 III A

Serious Gravity 10 2 instances 1 exposed
Issued
Oct 18, 2019
Abate by
Nov 14, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1408(a)(2)(iii): Option (3)-Table A clearance. The employer ailed to determine the line's voltage and the minimum approach distance permitted under Table A (see 29 CFR 1926.1408):  On or about April 22, 2019, at 6320 SW 8th Street, Miami, Florida, 33101, the employer failed to ensure the load line and load of a tower crane were maintained a distance away from energized power lines with the use of  recommendations made by the utility owner or registered professional engineer, thus exposing employees to an electrocution hazard.  NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1408 D01

Serious Gravity 10 2 instances 1 exposed
Issued
Oct 18, 2019
Abate by
Nov 14, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1408(d)(1): Part(s) of equipment, load line, or load (including rigging and lifting accessories) were allowed below an energized power line when the acceptions to paragraph (d)(2) did not apply:  On or about April 22, 2019, at 6320 SW 8th Street, Miami, Florida, 33101, employees were exposed to an electrocution hazard while operating a tower crane with its load line, load, and parts below energized power lines.  NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1417 C01

Serious Gravity 10 2 instances 1 exposed
Issued
Oct 18, 2019
Abate by
Nov 30, 2019
Penalty
Initial $9,282 · Current $6,497 Reduced
29 CFR 1926.1417(c)(1): The procedures applicable to the operation of the equipment, including rated capacities (load charts), recommended operating speeds, special hazard warnings, instructions, and operator's manual, were not readily available in the cab at all times for use by the operator:     On or about April 22, 2019, at 6320 SW 8th Street, Miami, Florida, 33101, employees were exposed to an electrocution hazard while a tower crane was operating near energized electrical lines without procedures for operation and the operators manual not being available in the cabin, thus exposing employees to an electrocution hazard.      NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $6497
  • — Z (S) $9282

1926.1418

Serious Gravity 10 2 instances 1 exposed
Issued
Oct 18, 2019
Abate by
Nov 14, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1418: The operator did not have the authority to stop and refuse to handle loads until a qualified person has determined that safety has been assured:  On or about April 22, 2019, at 6320 SW 8th Street, Miami, Florida, 33101, employees were exposed to an electrocution hazard while a tower crane was operating near energized electrical lines and its operator did not have the authority to stop and refuse to handle loads hoisted by the equipment.    NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1430 G01

Serious Gravity 10 2 instances 1 exposed
Issued
Oct 18, 2019
Abate by
Nov 30, 2019
Penalty
Initial $9,282 · Current $6,497 Reduced
29 CFR 1926.1430(g)(1): The employer did not evaluate each employee required to be trained under this subpart to confirm understanding of the training:    On or about April 22, 2019, at 6320 SW 8th Street, Miami, Florida, 33101, the employer failed to evaluate an operator of a tower crane prior to hoisting loads with the equipment near energized electrical lines, thus exposing employees to an electrocution hazard.      NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $6497
  • — Z (S) $9282

View Hi-Rise Crane, INC.'s full OSHA safety record →