OSHA Inspection: CMES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CMES, INC. in 6555 MCDONOUGH DRIVE, NORCROSS, GA 30093 (NAICS 237310). OSHA activity number 344097811.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cmes, INC. — free Get an email when a new federal OSHA severe-injury report for Cmes, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
CMES, INC.
Site address
6555 MCDONOUGH DRIVE
City
NORCROSS
State
GA
ZIP
30093
Mailing
6555 MCDONOUGH DRIVE, NORCROSS, GA 30093
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
75
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 7, 2019
Abate by
Sep 20, 2019
Penalty
Initial $9,282 · Current $6,126 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employement and a place of employement which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to electrical and struck-by hazards when working with automotive lifts:      On or about June 19 at 6555 McDonough Drive, Norcross, Georgia employees operating the automotive lift were exposed to struck-by, and caught-by hazards to include, but not limited to:    a.  employees were not trained in the safe use and operation of the lift using the manufacturers-provided instructions and warning labels .    b. the employer did not maintain the appropriately document operator training by completing the operator training log.    c. the employer did not establish a periodic inspection procedure in accordance with the recommendations of the lift manufacturer in order to ensure reliability and allow the continued safe operation of the lift.    d.  a record of each periodic inspection was not prepared and maintained noting the observations and findings of all points of inspection recommended by the manufacturer as well as subsequent repairs or replacements accomplished.
Recent events (2)
  • — I (S) $6126.12
  • — Z (S) $9282

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 7, 2019
Abate by
Aug 19, 2019
Penalty
Initial $6,763 · Current $4,464 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  On or about June 19, 2019 at 6555 McDonough Drive, Norcross, Ga. employees working with the Jet drill press were exposed to a caught-by hazard when the guard covering the drill was broken off and never replaced.
Recent events (2)
  • — I (S) $4463.58
  • — Z (S) $6763

1910.215 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 7, 2019
Penalty
Initial $4,508 · Current $2,975 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch.  On or about June 19, 2019 at 6555 McDonough Drive, Norcross, Ga. employees working with the  Jet bench grinder to shape parts and sharpen tools were exposed to a struck-by hazard when the opening on the work rest(s) exceeded 1/8" or were missing.
Recent events (2)
  • — I (S) $2975.28
  • — Z (S) $4508

1910.215 B09

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch.  On or about June 19, 2019 at 6555 McDonough Drive, Norcross, Ga. employees working with the Jet bench grinder to shape parts and sharpen tools were exposed to a struck-by hazard when the tongue guard(s) were not properly adjusted.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 II

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 7, 2019
Abate by
Aug 13, 2019
Penalty
Initial $9,282 · Current $6,126 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior.  On or about June 19, 2019 at 6555 McDonough Drive, Norcross, Ga. employees were exposed to an explosion/fire hazard when oxygen and acetylene were stored together on the chain link fence in the shop area.
Recent events (2)
  • — I (S) $6126.12
  • — Z (S) $9282

1910.303 B07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 7, 2019
Abate by
Aug 13, 2019
Penalty
Initial $4,508 · Current $2,975 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.  On or about June 19, 2019 at 6555 McDonough Drive, Norcross, Ga. employees accessing the breaker inside the electrical panel to access the lights for the shop were exposed to an electrical shop hazard when unused openings were not effectively closed.
Recent events (2)
  • — I (S) $2975.28
  • — Z (S) $4508

1910.305 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 7, 2019
Abate by
Aug 19, 2019
Penalty
Initial $5,636 · Current $3,720 Reduced
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:  On or about June 19, 2019 at 6555 McDonough Drive, Norcross, GA. employees were exposed to electrical hazards, to include, but not limited to :  a.   on the four post truck lift, in the shop area  the opening through which conductors entered the motor housing were not effectively closed.  b.  at the electrical panel, wiring to the HVAC was not protected from abrasion when fitting was not placed on the wiring.
Recent events (2)
  • — I (S) $3719.76
  • — Z (S) $5636

1910.305 G02 III

Serious Gravity 5 1 instance 8 exposed
Issued
Aug 7, 2019
Abate by
Aug 19, 2019
Penalty
Initial $5,636 · Current $3,614 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    On or about June 12, 2019 at 6555 McDonough Drive, Norcross, Ga. employees were exposed to electrical hazards in the Shop Area.  Employer had improvised a cord and plug connection to the junction box on the electric motor of the "Rotary" model SM30N012, four post truck lift using and strain relief was not provided to the conductors entering the plug.
Recent events (2)
  • — I (S) $3613.86
  • — Z (S) $5636