Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PIM CORPORATION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of PIM CORPORATION in WAR MEMORIAL MONTGOMERY STREET, SYRACUSE, NY 13202 (NAICS 237110). OSHA activity number 344114244.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PIM Corporation — free Get an email when a new federal OSHA severe-injury report for PIM Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
PIM CORPORATION
Site address
WAR MEMORIAL MONTGOMERY STREET
City
SYRACUSE
State
NY
ZIP
13202
Mailing
201 CIRCLE DRIVE SUITE 105, PISCATAWAY, NJ 08854
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
14
Ownership type
A

2 citations on file for this inspection.

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 16, 2019
Abate by
Aug 5, 2019
Penalty
Initial $1,932 · Current $1,449 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace.  a) Onondaga County War Memorial on Montgomery Street in Syracuse, NY 13202, on or about 6/27/19: A medical evaluation was not performed for an employee wearing a half face air purifying respirator.   Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1449
  • — Z (S) $1932

1910.134 F01

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 16, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):   a) Onondaga County War Memorial on Montgomery Street in Syracuse, NY 13202, on or about 6/27/19: An employee wearing a tight fitting half face air purifying respirator did not pass a fit-test.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View PIM Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344114244.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.