SAINT LOUIS, MO —
OSHA Inspection: RESPONSIBLE CONTAINER LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of RESPONSIBLE CONTAINER LLC in 5300 HALL STREET, SAINT LOUIS, MO 63147 (NAICS 423930). OSHA activity number 344132857.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RESPONSIBLE CONTAINER LLC
- Site address
- 5300 HALL STREET
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63147
- Mailing
- 5300 HALL STREET, SAINT LOUIS, MO 63147
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 60
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.36 G02
- Issued
- Nov 7, 2019
- Abate by
- Dec 5, 2019
- Penalty
- Initial $3,978 · Current $1,989 Reduced
General-duty citation text
29 CFR 1910.36 (g) (2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points: Drum Label Removing area: Employer is exposing employees to hazardous conditions. The employer permits employees to use an exit route which is less than 28 inches wide. On 07/25/2019 employees used an exit route which measured approximately 13 inches wide.
Recent events (2)
- — I (S) $1989
- — Z (S) $3978
1910.95 C01
- Issued
- Nov 7, 2019
- Abate by
- Dec 5, 2019
- Penalty
- Initial $6,630 · Current $3,315 Reduced
8111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: Drum Label Removal area: Employer is exposing employees to hazardous conditions. The employer permits the employees to work where they are exposed to noise at levels above 85 decibels without a hearing conservation program in place. On 07/09/2019 employees were exposed to noise at 89.0 dBA and 88.6 dBA. Noise sampling was conducted for 437 minutes and 444 minutes respectively. The employees were not provided a hearing conservation program to prevent hearing loss.
Recent events (2)
- — I (S) $3315
- — Z (S) $6630
1910.212 A05
- Issued
- Nov 7, 2019
- Abate by
- Dec 5, 2019
- Penalty
- Initial $6,630 · Current $3,315 Reduced
General-duty citation text
29 CFR 1910.212 (a) (5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: Paint Booth area: Employer is exposing employees to hazardous conditions. The employer permits the employees to work where they are exposed to the hazards of rotating metal blades of an unguarded pedestal fan. On 08/06/2019 the employees were exposed to rotating hazards where a pedestal fan with unguarded metal blades was used.
Recent events (2)
- — I (S) $3315
- — Z (S) $6630
1910.303 G02 I
- Issued
- Nov 7, 2019
- Abate by
- Dec 5, 2019
- Penalty
- Initial $6,630 · Current $3,316 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): 29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: Paint Booth area: Employer is exposing employees to hazardous conditions. The employer permits the employees to work where they are exposed to electrical hazards where a pedestal fan is energized from electrical equipment with exposed energized parts. On 08/06/2019 the employees were exposed to electrical hazards where the powered cord of a pedestal fan with unguarded metal blades was connected to electrical equipment with exposed energized parts.
Recent events (2)
- — I (S) $3316
- — Z (S) $6630
1910.22 A01
- Issued
- Nov 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): Places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition: Drum Label Removing area: Employer is exposing employees to hazardous conditions where employees' workplace is not kept sanitary. On 06/19/2019 employees worked in an area which was not kept in a sanitary state. There were removed labels on the workplace floor and accumulations of refuse.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Responsible Container LLC
View Responsible Container LLC's full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in MO
Source