Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RESPONSIBLE CONTAINER LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of RESPONSIBLE CONTAINER LLC in 5300 HALL STREET, SAINT LOUIS, MO 63147 (NAICS 423930). OSHA activity number 344132857.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Responsible Container LLC — free Get an email when a new federal OSHA severe-injury report for Responsible Container LLC is published. One employer, no account, unsubscribe in one click.
Site address
5300 HALL STREET
City
SAINT LOUIS
State
MO
ZIP
63147
Mailing
5300 HALL STREET, SAINT LOUIS, MO 63147
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
60
Ownership type
A

5 citations on file for this inspection.

1910.36 G02

Serious Gravity 1 1 instance 6 exposed
Issued
Nov 7, 2019
Abate by
Dec 5, 2019
Penalty
Initial $3,978 · Current $1,989 Reduced
29 CFR 1910.36 (g) (2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:     Drum Label Removing area: Employer is exposing employees to hazardous conditions.  The employer permits employees to use an exit route which is less than 28 inches wide.     On 07/25/2019 employees used an exit route which measured approximately 13 inches wide.
Recent events (2)
  • — I (S) $1989
  • — Z (S) $3978

1910.95 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 7, 2019
Abate by
Dec 5, 2019
Penalty
Initial $6,630 · Current $3,315 Reduced

Hazardous substances 8111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:         Drum Label Removal area:  Employer is exposing employees to hazardous conditions.  The employer permits the employees to work where they are exposed to noise at levels above 85 decibels without a hearing conservation program in place.     On 07/09/2019 employees were exposed to noise at 89.0 dBA and 88.6 dBA.  Noise sampling was conducted for 437 minutes and 444 minutes respectively. The employees were not provided a hearing conservation program to prevent hearing loss.
Recent events (2)
  • — I (S) $3315
  • — Z (S) $6630

1910.212 A05

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 7, 2019
Abate by
Dec 5, 2019
Penalty
Initial $6,630 · Current $3,315 Reduced
29 CFR 1910.212 (a) (5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:     Paint Booth area: Employer is exposing employees to hazardous conditions.  The employer permits the employees to work where they are exposed to the hazards of rotating metal blades of an unguarded pedestal fan.     On 08/06/2019 the employees were exposed to rotating hazards where a pedestal fan with unguarded metal blades was used.
Recent events (2)
  • — I (S) $3315
  • — Z (S) $6630

1910.303 G02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 7, 2019
Abate by
Dec 5, 2019
Penalty
Initial $6,630 · Current $3,316 Reduced
29 CFR 1910.303(g)(2)(i): 29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:     Paint Booth area: Employer is exposing employees to hazardous conditions.  The employer permits the employees to work where they are exposed to electrical hazards where a pedestal fan is energized from electrical equipment with exposed energized parts.         On 08/06/2019 the employees were exposed to electrical hazards where the powered cord of a pedestal fan with unguarded metal blades was connected to electrical equipment with exposed energized parts.
Recent events (2)
  • — I (S) $3316
  • — Z (S) $6630

1910.22 A01

Other-than-serious 1 instance 6 exposed
Issued
Nov 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): Places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition:  Drum Label Removing area: Employer is exposing employees to hazardous conditions where employees' workplace is not kept sanitary.  On 06/19/2019 employees worked in an area which was not kept in a sanitary state.  There were removed labels on the workplace floor and accumulations of refuse.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Responsible Container LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344132857.