Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NICHE POLYMER, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NICHE POLYMER, LLC in 880 S. WASHINGTON STREET, RAVENSWOOD, WV 26164 (NAICS 325211). OSHA activity number 344145164.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Niche Polymer, LLC — free Get an email when a new federal OSHA severe-injury report for Niche Polymer, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
NICHE POLYMER, LLC
Site address
880 S. WASHINGTON STREET
City
RAVENSWOOD
State
WV
ZIP
26164
Mailing
880 S. WASHINGTON STREET, RAVENSWOOD, WV 26164
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
90
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Other-than-serious Gravity 10 1 instance 3 exposed
Issued
Nov 15, 2019
Abate by
Dec 12, 2019
Penalty
Initial $9,282 · Current $7,426 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) 8" Pelletizer: On July 9, 2019 and times prior, the employer used established procedures that were not adequately developed, documented or utilized to address the control of all potentially hazardous energy on equipment such as, but not limited to, the Cumberland 8" pelletizer, which contained gravitational energy and 480V electrical energy.  (b) 17" Pelletizer: On or about October 23, 2019 and times prior, the employer used established procedures that were not adequately developed, documented or utilized to address the control of all potentially hazardous energy on equipment such as, but not limited to, the Cumberland 17" pelletizer, which contained approximately 75psi pneumatic energy and 480V electrical energy.
Recent events (3)
  • — F (O) $7425.6
  • — C (S) $9282
  • — Z (S) $9282

1910.147 D02

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Nov 15, 2019
Abate by
Dec 12, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:  (a) Line 10: On July 9, 2019 and times prior, employees would perform servicing and maintenance activities on the 8" Cumberland pelletizer without first turning off or shutting down the equipment, to include addressing the gravitational energy as well as the 480V electrical energy.  (b) 17" Pelletizer: On or about October 23, 2019 and times prior, employees would perform servicing and maintenance activities on the 17" Cumberland pelletizer without first fully turning off or shutting down the equipment, to include addressing the approximately 75psi pneumatic energy and 480V electrical energy.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Niche Polymer, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344145164.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.