On , OSHA opened a planned safety inspection of CORBARA-MGS JV in NBSD B3477 HARBORSIDE GYM, SAN DIEGO, CA 92136 (NAICS 236220). OSHA activity number 344146881.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORBARA-MGS JV
- Site address
- NBSD B3477 HARBORSIDE GYM
- City
- SAN DIEGO
- State
- CA
- ZIP
- 92136
- Mailing
- 711 A AVENUE, NATIONAL CITY, CA 91950
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.404 B01 I
- Issued
- Aug 5, 2019
- Abate by
- Aug 15, 2019
- Penalty
- Initial $1,932 · Current $1,932
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: Renovation Area: General contractor employee(s) were using flexible cords to provide power to a laptop computer, printer, and phone charger without ground fault circuit interrupters. Employees were exposed to electrical shock hazards.
Recent events (1)
- — Z (S) $1932
1926.403 B02
- Issued
- Aug 5, 2019
- Abate by
- Aug 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Renovation Area: General contractor employee(s) were using an extension cord and relocatable power tap to concurrently provide power to a laptop computer, printer, and phone charger. Employees were exposed to fire hazards. b) B3477 Locker Room: Subcontractor employees were performing carpentry work, such as cutting and stapling templates for the shower wall. A Rigid 5-outlet power tap was used to concurrently provide power to hand tools and another 3-outlet power tap. Employees were exposed to fire hazards.
Recent events (1)
- — Z (O) $0
More inspections at Corbara-Mgs JV
View Corbara-Mgs JV's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344146881.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.