KETCHIKAN, AK —
OSHA Inspection: FOREST SERVICE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FOREST SERVICE in 3031 TONGASS AVENUE, KETCHIKAN, AK 99901 (NAICS 924120). OSHA activity number 344154125.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FOREST SERVICE
- Site address
- 3031 TONGASS AVENUE
- City
- KETCHIKAN
- State
- AK
- ZIP
- 99901
- Mailing
- 3031 TONGASS AVENUE, KETCHIKAN, AK 99901
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 924120
- Employees
- 20
- Ownership type
- D
Citations
10 citations on file for this inspection.
1910.28 B03 II
- Issued
- Aug 6, 2019
- Abate by
- Aug 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(3)(ii): Each employee was not protected from tripping into or stepping into or through any hole that was less than 4 feet (1.2 m) above a lower level by covers or guardrail systems: Auto Shop, Restroom: On or about July 10, 2019 and at times prior thereto, a floor hole measuring 78 inches, by 18 inches was not protected from tripping or stepping into. This condition exposed employees to a fall hazard of 24 inches.
Recent events (1)
- — Z (S) $0
1910.37 A04
- Issued
- Aug 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: Bunk House: On or about July 10, 2019 and at times prior thereto, fire doors in the first floor hallway were blocked open. This condition exposed employees/tenants to smoke-inhalation hazards.
Recent events (1)
- — Z (S) $0
1910.37 B02
- Issued
- Aug 6, 2019
- Abate by
- Aug 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit:" (a) Bunkhouse, Front Entrance: On or about July 10, 2019 and times prior thereto, the exit was not marked by a sign reading "Exit." This condition exposed employees to smoke-inhalation hazards from delay in identifying exit. (b) Bunkhouse, Rear Entrance: On or about July 10, 2019 and times prior thereto, the exit was not marked by a sign reading "Exit." This condition exposed employees to smoke-inhalation hazards from delay in identifying exit.
Recent events (1)
- — Z (S) $0
1910.37 B07
- Issued
- Aug 6, 2019
- Abate by
- Aug 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(7): Each exit sign did not have the word "Exit" in plainly legible letters not less than six inches (15.2 cm) high, with the principal strokes of the letters in the word "Exit" not less than three-fourths of an inch (1.9 cm) wide: (a) Bunkhouse, Front Stairwell Access, 2nd Floor: On or about July 10, 2019 and at times prior thereto, the letter of the exit sign were 2.5 inches in height and 0.5 inches in width. This condition limited identification of the Exit. (b) Bunkhouse, Rear Stairwell Access, 2nd Floor: On or about July 10, 2019 and at times prior thereto, the letter of the exit sign were 2.5 inches in height and 0.5 inches in width. This condition limited identification of the Exit.
Recent events (1)
- — Z (S) $0
1910.141 A03 II
- Issued
- Aug 6, 2019
- Abate by
- Aug 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(a)(3)(ii): Floor(s) of workroom(s) were not maintained, so far as practical, in a dry condition: Bunkhouse, Boiler Room: On or about July 10, 2019 and at times prior thereto, water had accumulated on the floor. This condition exposed employees to a slip hazard.
Recent events (1)
- — Z (S) $0
1910.212 B
- Issued
- Aug 6, 2019
- Abate by
- Aug 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: Wood Shop: On or about July 10, 2019 and at times prior thereto, a Delta Drill was not securely anchored. This condition exposed employees to struck-by hazards.
Recent events (1)
- — Z (S) $0
1910.215 A04
- Issued
- Aug 6, 2019
- Abate by
- Aug 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) Wood Shop: On or about July 10, 2019 and at times prior thereto, the work rest for the right-side abrasive wheel on a Craftsman 8 inch bench grinder was set at three-eighth inch. This condition exposed employees to caught-in hazards. 29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: (b) On or about July 10, 2019 and at times prior thereto, the work rest for the left-side abrasive wheel on a Craftsman 8 inch bench grinder was removed. This condition exposed employees to caught-in hazards.
Recent events (1)
- — Z (S) $0
1910.242 B
- Issued
- Aug 6, 2019
- Abate by
- Aug 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: Auto Shop: On or about July 10, 2019 and at times prior thereto, compressed air for cleaning measured 90 p.s.i.g. at the nozzle tip. This condition exposed employees to air embolism hazards.
Recent events (1)
- — Z (S) $0
1910.303 F01
- Issued
- Aug 6, 2019
- Abate by
- Aug 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: Wood Shop: On or about July 10, 2019 and at times prior thereto, the Square D disconnect was not legibly marked to indicate its intended purpose. This condition limited employee information in the event a facility component had to be deenergized.
Recent events (1)
- — Z (S) $0
1910.141 A04 I
- Issued
- Aug 6, 2019
- Abate by
- Aug 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(a)(4)(i): Receptacle(s) used for putrescible solid or liquid waste or refuse were not equipped with tight fitting cover(s) necessary to maintain sanitary conditions: Bunkhouse, Kitchen: On or about July 10, 201 and at times prior thereto, the garbage receptacle did not have a tight-fitting cover. This exposed employees to unsanitary conditions in a food preparation area.
Recent events (1)
- — Z (O) $0
More inspections at Forest Service
View Forest Service's full OSHA safety record →
More inspections in this industry (NAICS 924120)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344154125.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.